Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberFIR11-00588
StatusFinaled
Name NORTHWEST SALES COMPANY
Site Address 913 W RIVER ST
Project NameCOTTONWOOD GRILLE
Customer Number 
ePlanReviewNo
Description
This fire alarm permit is to extend the existing manual fire alarm system throughout the tenant space. This permit scope of work includes two new pull stations, new notification devices to provide full notification coverage, and a new NAC extender panel to accommodate the new notification devices.

Associated building permit: BLD11-02361 (COTTONWOOD GRILLE - BANQUET ROOM EXPANSION) Parcels need to be consolidated per Density Reduction Survey (4368). New deed required to be recorded before occupancy. The fire sprinkler system substitutes for the 1-hr construction of the building. To expand an existing 7,266 square foot restaurant into an adjacent 1,416 square foot area (i.e. a 1,050 square foot banquet room and a 366 square foot food staging room). After the expansion this tenant space will have a total floor area of about 8,682 square feet (10,682 square feet including the 2,000 square foot exterior deck). Work is to include upgrading the existing floor construction to comply as a 1-hr fire-resistance-rated horizontal assembly (i.e. floor) with 1-hr fire-resistance-rated supporting construction (i.e. beams and columns). A 1-hr fire-resistance-rated fire barrier wall with a 45 minute door will also be constructed. The intent is to completely separate the restaurant, including the new banquet room and food staging area, from the rest of the building with a 1-hr fire-resistance-rated occupancy separation (i.e. separated uses). Work also includes interior nonbearing walls, gypsum board soffits, suspended acoustical ceilings, and doors. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. The fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. The egress systems for occupied areas of this building are required to be maintained unobstructed. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  2/24/2012 DONE
plans taken to records for scanning
INSP-Final Inspection1/25/20121/26/20121/26/2012APASS
DetailsForrest France
Functional testing passed. Fire alarm permit finaled.
Issue and Print Permit  11/14/2011 DONE
DetailsBarbara Stitt
Plan assigned to (Stephanie)11/3/2011 11/10/2011 DONE
DetailsStephanie L. Cobbley
1st review completed  11/10/2011 DONE
Alarm Plan Check11/10/2011 11/10/2011 PASS
DetailsStephanie L. Cobbley
Plans approved with redlines and review comments.
PLANS TAKEN FRONT DESK ALARM  11/10/2011 DONE
Approved redlined plans available at front counter.
Inspection Record Card- Fire11/10/2011 11/10/2011 DONE
DetailsPatricia Smith
Telephone call  11/10/2011 DONE
t/c w david - permit ready and fees given
Permit Ready to Issue  11/10/2011 DONE
Details
Application received  11/3/2011