Permit Information
Permit NumberFIR11-00594
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 3869 N GARDEN CENTER WAY
Project NameLive/Work Unit #28
Customer Number 
ePlanReviewNo
Description
The Fire Sprinkler Scope of work consists of providing a 13D sprinkler system for a live/work unit. Extended coverage residential sprinklers were utilized with vary spacing (please see hydraulic summary for details).


Building Department Scope:

(live/work unit 28) *** 11/3/11 PLAN MODIFICATION TO INCLUDE: CONSTRUCTION OF 45 LINEAL FEET OF NEW INTERIOR NON-BEARING WALL PARTIONS TO CREATE A CONFERENCE ROOM AND AN OFFICE WITH TWO DOORS PER THE APPROVED PLANS AND STRUCTURAL INSPECTORS FINAL APPROVALS. *** To construct a 1850 sq.ft., two story, Live/Work unit (Townhouse) on a zero lot line. The First story includes a 713 sq.ft. non-residential use, operated by the tenant and shall comply with section 419 of the 2007 International Building Code Supplement. The first story also has a 37 sq.ft. covered porch, a 27 sq.ft. covered patio, and a 464 sq.ft. attached two car garage. A maximum of five non-residential workers or employees are allowed to occupy the non-residential area at any one time. The second story includes a 1137 sq.ft., two bedroom, two bathroom, dwelling unit with a 89 sq.ft. balcony. The dwelling unit shall comply with the 2006 International Residential Code for a Single family townhouse dwelling. This building shall conform to section 903.3.1.3 of the 2006 IBC. An automatic sprinkler system shall be installed throughout in accordance with NFPA 13D. Any and all NFPA 13D systems shall be equipped with an alarm initiating device commonly referred to as a flow switch, and an outside alarm indicating device. A Fire Sprinkler Permit is required prior to beginning any fire sprinkler work. "This lot is within a Floodplain area. An elevation certificate is required to be submitted to and approved by Jim Wyllie, Public Works Department, prior to calling for a framing inspection." All work per the approved plans, engineering, plan review report, and alternate agreements on file. DRH07-00466, DRH08-00126, and CUP07-00121 per Planning and Zoning. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  4/24/2012 DONE
DetailsTim Frost
Sent to Records for scanning.
INSP-Final Inspection12/30/20111/3/20121/3/2012APASS
DetailsTroy Cobbley
Permit finaled
INSP-Final Inspection12/28/201112/30/201112/30/2011ADEFR
DetailsForrest France
Overbooked
INSP-Sprinkler Rough-in11/15/201111/16/201111/16/2011PPASS
DetailsTroy Cobbley
Sprinkler piping can be covered.
Issue and Print Permit  11/10/2011 DONE
Sprinkler Plan Check11/8/2011 11/8/2011 PASS
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
1st review completed  11/8/2011 DONE
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  11/8/2011 DONE
DetailsTim Frost
Inspection Record Card- Fire11/8/2011 11/8/2011 DONE
DetailsPatricia Smith
Telephone call  11/8/2011 DONE
t/c w melody - permit ready and fees given
Permit Ready to Issue  11/8/2011 DONE
Details
Application received  11/7/2011 DONE
DetailsBarbara Stitt
Case Summary  11/7/2011 DONE
DetailsBarbara Stitt