Permit Information
Permit NumberFIR11-00621
StatusFinaled
Name ALLIED GENERAL FIRE & SECURITY
Site Address 13626 W BALDCYPRESS ST
Project NameTRADITIONS - SECTION A
Customer NumberUDG ONLY
ePlanReviewNo
Description
The Fire Sprinkler Scope of work consists of 6”x 155’ of C-900 underground piping with associated fittings and thrust blocks.

Note: See FIR11-00563 for the above ground permit
Note: See FIR11-.00517 for the in building riser permit

Building Department Scope:

There are three building permits for this project.

BLD11-01267
TRADITIONS AT BOISE LLC- Section A- Section 'A' (West Wing) to construct a four story 1-hour fire rated, wood frame, 52-unit, commercial apartment building of 25,296 sq. ft.(6412 s.f. - 1st fl / 6,497 s.f. - 2 thru 4th fl.). There are 12 units @742 s.f.; 4 @ 751 s.f.; 4 @ 553 s.f. and 12 @ 568 s.f.. A 2-hour combination fire wall & Horizontal exit is being constructed between the West Wing and Center Core portion for allowable area compliance. This building is fully sprinkler W/ 13R system for allowable area increase, addition of 1-story and for occupancy use compliance; alarm with notification system; 1-hour exit corridors connecting the 2-hour stair enclosure and horizontal exit; and mechanical shaft assemblies are indicated as 2-hour rated. Each floor has one exit into a rated stair enclosure and 1 exit through a horizontal exit. All work to be in accordance with the reviewed plans, red-lined notes on plans and attached plan review comments & conditions of all provided plan reviews. CUP10-00052 DRH10-00222

BLD11-01268
TRADITIONS AT BOISE LLC-Section B- Section 'B' (Center Core) to construct a four story 1-hour fire rated, wood frame, 66-unit, commercial apartment building of 64,558 sq. ft.(16,519 s.f. - 1st fl / 16,013 s.f. - 2 thru 4th fl.). There are 13 units @ 742 s.f.; 4 @ 553 s.f. and 28 @ 568 s.f.; 3 @ 762 s.f.; 6 @ 540 and 12 @ 457 s.f. The first floor Center Core has accessory support areas.Two (2) 2-hour combination fire walls & Horizontal exits are being constructed between the West Wing / Center Core and East Wing / Center Core portions for allowable area compliance of Center Core. There is also a 2-hour exit stair enclosure toward the west end of the Center core. This building is fully sprinkler W/ 13R system for allowable area increase, addition of 1-story and for occupancy use compliance; alarm with notification system; 1-hour exit corridors connecting the 2-hour stair enclosure and both horizontal exits; and mechanical shaft assemblies are indicated as 2-hour rated. Each floor has one exit into a rated stair enclosure and 2 exits through a horizontal exit. All work to be in accordance with the reviewed plans, red-lined notes on plans and attached plan review comments & conditions of all provided plan reviews. CUP10-00052 DRH10-00222

BLD11-01269
TRADITIONS AT BOISE LLC-Section C- Section 'C' (East Wing) to construct a four story 1-hour fire rated, wood frame, 52-unit, commercial apartment building of 46,938 sq. ft.(11,685 s.f. - 1st fl / 11,751 s.f. - 2nd thru 4th fl.). There are 18 units @742 s.f.; 1 @ 759 s.f.; 12 @ 553 s.f. and 12 @ 568 s.f.. 4 @ 731 s.f.; 5 @ 762 s.f. A 2-hour combination fire wall & Horizontal exit is being constructed between the East Wing and Center Core portion for allowable area compliance. This building is fully sprinkler W/ 13R system for allowable area increase, addition of 1-story and for occupancy use compliance; alarm with notification system; 1-hour exit corridors connecting the 2-hour stair enclosure and horizontal exit; and mechanical shaft assemblies are indicated as 2-hour rated. Each floor has one exit into a rated stair enclosure and 1 exit through a horizontal exit. All work to be in accordance with the reviewed plans, red-lined notes on plans and attached plan review comments & conditions of all provided plan reviews. CUP10-00052 DRH10-00222
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection7/2/20127/2/20127/2/2012PPASS
DetailsTroy Cobbley
Permit finaled
FIR-Aging Inspection5/16/20125/16/20125/24/2012 NR
DetailsTroy Cobbley
Work is in progress
INSP-Supply line flush1/16/20121/17/20121/17/2012PPASS
DetailsTroy Cobbley
The underground flush passed.
INSP-Sprinkler Rough-in1/17/20121/17/20121/17/2012PPASS
DetailsTroy Cobbley
Underground supply line is ok to cover.
INSP-Sprinkler Rough-in/Hydro12/19/201112/20/201112/19/2011APASS
DetailsTroy Cobbley
UG supply line hydro test passed
INSP-Supply line flush12/16/201112/16/201112/16/2011PCANC
DetailsTroy Cobbley
Not ready.
INSP-Supply line flush12/14/201112/15/201112/15/2011PCANC
DetailsTroy Cobbley
cancel per john
Plan assigned to (Tim)11/18/2011 11/23/2011 DONE
DetailsTim Frost
Sprinkler Plan Check11/23/2011 11/23/2011 PASS
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
1st review completed  11/23/2011 DONE
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  11/23/2011 DONE
DetailsTim Frost
Inspection Record Card- Fire11/23/2011 11/23/2011 DONE
DetailsPatricia Smith
Telephone call  11/23/2011 DONE
left vm for jim - permit ready and fees given
Permit Ready to Issue  11/23/2011 DONE
Details
Issue and Print Permit  11/23/2011 DONE
Application received  11/18/2011