Permit NumberFIR12-00004
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 10259 W EMERALD ST Unit: 160
Project NameBASELINE INC STE 160
Customer Number 
ePlanReviewNo
Description
The Fire Sprinkler Scope of work consists of add and relocating sprinklers to accommodate new wall and ceiling construction. A portion of the space is changing from light hazard back to ordinary hazard II. The existing system is a 4”x3”x1½” grid with a 4” riser and 4” backflow preventer. The system utilizes extended coverage sprinklers. A portion of the system (manufacturing area) has a change of occupancy from light hazard to ordinary hazard


Building Department Scope:

(BASELINE, llc – Emerald Bldg “D” – Ste # 160) Permit is remodel an exsiting13,276 square foot tenant space be expanding into 1,358 square feet of vacant tenant space adjacent to this space. Also this remodel will change the primary use of this building from athletic training to office and fabrication. Approval contingent upon adhering to the approved plans on file. Work to include: [construction of a noncombustible / nonbearing interior walls to create 12 new office spaces, an R&D area, an Engineering room, an Environmental Testing room, a manufacturing area, a break room and a conference room], installation of new lighting, installation of new accessible doors / hardware, installation of a new sink, modify the existing HVAC system, and interior finishes. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **TLW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  4/24/2012 DONE
DetailsTim Frost
Sent to Records for scanning.
INSP-Final Inspection1/25/20121/30/20121/30/2012PPASS
DetailsTroy Cobbley
permit finaled
INSP-Sprinkler Rough-in1/17/20121/17/20121/17/2012PPASS
DetailsTroy Cobbley
Sprinkler piping can be covered. I noted several areas where the existing sprinkler pendants are located too close together and located too far off of walls.
Plan assigned to (Tim)1/6/2012 1/10/2012 DONE
DetailsTim Frost
Sprinkler Plan Check1/10/2012 1/10/2012 PASS
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
1st review completed  1/10/2012 DONE
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  1/10/2012 DONE
DetailsTim Frost
Permit Ready to Issue  1/10/2012 DONE
DetailsBarbara Stitt
Inspection Record Card- Fire1/10/2012 1/10/2012 DONE
DetailsBarbara Stitt
Telephone call  1/10/2012 DONE
DetailsBarbara Stitt
Called Jeff Anderson and told him that permit is ready & fees due on 1-10-12 @ 2:15pm//BAS
Issue and Print Permit  1/10/2012 DONE
Plan assigned to (Tim)1/5/2012 1/6/2012 DONE
DetailsTim Frost
1st review completed  1/6/2012 PASS
DetailsTim Frost
Application received  1/5/2012