Miscellaneous action | | | 9/23/2013 | | DONE |
Tim Frost
|
|
|
Sent to Records for scanning.
|
INSP-Final Inspection | 3/20/2013 | 3/22/2013 | 3/22/2013 | A | PASS |
Troy Cobbley
|
|
|
Permit finaled
|
FIR-Aging Inspection | 2/28/2013 | 2/28/2013 | 2/28/2013 | | NR |
Troy Cobbley
|
|
|
Work is in progress
|
INSP-Sprinkler Rough-in | 11/8/2012 | 11/9/2012 | 11/9/2012 | A | PASS |
Troy Cobbley
|
|
|
Third floor tenting has been corrected and the plans revised. Third floor piping can be covered.
|
Sprinkler Plan Check | 11/8/2012 | | 11/8/2012 | | PASS |
Tim Frost
|
|
|
Please, see attached comments.
There are NO annotations on the plans.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/8/2012 | | DONE |
Tim Frost
|
|
|
|
Telephone call | | | 11/8/2012 | | DONE |
Christina Prado
|
|
|
Called jonathan to advise permit is ready and gave fees due
|
Permit Ready to Issue | | | 11/8/2012 | | DONE |
Christina Prado
|
|
|
|
Inspection Record Card- Fire | 11/8/2012 | | 11/8/2012 | | DONE |
Christina Prado
|
|
|
|
(F) Reprint permit | | | 11/8/2012 | | DONE |
|
|
|
|
CHANGE STATUS TO (ISS) | | | 11/8/2012 | | DONE |
|
|
|
|
Plan assigned to (Tim) | 11/6/2012 | | 11/8/2012 | | DONE |
Tim Frost
|
|
|
|
INSP-Sprinkler Rough-in | 11/7/2012 | 11/7/2012 | 11/7/2012 | P | PASS |
Troy Cobbley
|
|
|
The sprinkler piping on the first and second floors of this building can be covered. The third floor can not be covered due to piping and tenting issues. Potential problems exist on the first and second floors due to soffits. Contractor and I discussed the need for sprinkler spacing to meet NFPA 13R figure 6.4.6.3.4.3.
|
Plan resubmittals received | | | 11/6/2012 | | |
|
|
|
Plan modification
|
INSP-Sprinkler Rough-in | 11/1/2012 | 11/5/2012 | 11/5/2012 | A | FAIL |
Troy Cobbley
|
|
|
The first and second floor rough-in passed. There are some concerns that fixtures and possible soffits will be too close the the pendant heads. The third floor piping has alot of extra 90's in the piping including in the remote area. The pipe sizing does not match the plans either. I also noted that the tenting is not adequate in several areas. First and second floor piping only can be covered. Third floor piping needs to be resubmitted for review.
|
INSP-Sprinkler Rough-in/Hydro | 11/1/2012 | 11/5/2012 | 11/5/2012 | A | PASS |
Troy Cobbley
|
|
|
Overhead hydro test passed.
|
Issue and Print Permit | | | 10/8/2012 | | DONE |
|
|
|
|
Plan assigned to (Tim) | 8/6/2012 | | 8/29/2012 | | DONE |
Tim Frost
|
|
|
|
Sprinkler Plan Check | 8/29/2012 | | 8/29/2012 | | PASS |
Tim Frost
|
|
|
Please, see attached comments.
There are NO annotations on the plans.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/29/2012 | | DONE |
Tim Frost
|
|
|
|
Telephone call | | | 8/29/2012 | | DONE |
Christina Prado
|
|
|
Called JBL to advise permit is ready and gave fees due
|
Permit Ready to Issue | | | 8/29/2012 | | DONE |
Christina Prado
|
|
|
|
Inspection Record Card- Fire | 8/29/2012 | | 8/29/2012 | | DONE |
Christina Prado
|
|
|
|
Plan resubmittals received | | | 8/24/2012 | | |
|
|
|
|
Telephone call | | | 8/10/2012 | | DONE |
Barbara Stitt
|
|
|
Called and told plans were denied and need to pick up and re-submit on 8-9-12 @ 2:15pm//BAS
|
Sprinkler Plan Check | 8/9/2012 | | 8/9/2012 | | FAIL |
Tim Frost
|
|
|
Please, see attached comments.
There are NO annotations on the plans.
|
1st review completed | | | 8/9/2012 | | FAIL |
Tim Frost
|
|
|
|
Miscellaneous action | | | 8/9/2012 | | DONE |
Tim Frost
|
|
|
Emailed review to contractor
|
Application received | | | 8/6/2012 | | |
|
|
|
|