Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberFIR12-00428
StatusFinaled
Name CRANE ALARM COMPANY
Site Address 4262 N EAGLE RD
Project NameGRACE BIBLE CHURCH
Customer Number 
ePlanReviewNo
Description
This fire alarm permit is to provide a manual fire alarm system in a new building. This permit scope of work includes sprinkler system monitoring, a pull station, a smoke detector above the fire alarm control panel, notification throughout, HVAC monitoring/shutdown, monitoring for an antifreeze sprinkler systems, and a remote annunciator panel.
Associated building permit: BLD12-00551
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  2/14/2013 DONE
Plans taken to records for scanning
INSP-Final Inspection1/31/20131/31/20131/31/2013PPASS
DetailsTroy Cobbley
Permit finaled
Telephone call  1/31/2013 DONE
Tim w/ Crane alarm called. He wanted to know if they pull the mag locks out if they could get a temporary occupancy. I told him I can't authorize temps, but I did give him another option. I said that as long as his city approved plans matched the install (i.e. without the mag locks) that if his system passed inspection he would not need a temp due to this and I could cancel the plan modification that was submitted to add the locks. However, I told him in order to cancel the plan modification, I would need an email from him and a letter from the owner/representative that states they understand that a separate fire alarm permit would need to be applied for and approved PRIOR to installing the mag locks. I asked him to include in the email what their intent is (i.e. remove the mag locks and put the system back to the way it was already approved) and indicate if he wants to pick up his plan modifications or if he wants me to recycle them. I also let him know that adding the mag locks would not qualify for a quick permit because they would be adding a new circuit. He said he would get back to me.
Miscellaneous action  1/31/2013 DONE
Received emails from Tim at Crane alarm, From Joe Cacioppo (pastor of the church), and Jesse Ferrer (general contractor) stating they understand that a fire alarm permit will need to be submitted and approved prior to installing mag locks at the church. Tim asked that he pick up the cancelled plans rather than me recycling them.
Miscellaneous action  1/31/2013 DONE
I have asked the permit technicians to put the permit back to 'issued' status and have placed the plans at the permit counter drawer for Tim to pick up at his convenience.
CHANGE STATUS TO (ISS)  1/31/2013 DONE
DetailsTisha Gallop
per SLC decided not to do plan mod at this time, contractor coming to pick up plans.
Plan resubmittals received  1/29/2013 DONE
DetailsTisha Gallop
Plan Modification: Received two copes of plans and submittal folder
Telephone call  1/28/2013 DONE
Tim w/Crane Alarm called. A mag lock has been added and he wanted to know if he had to resubmit. I said that if there is not already an existing door release circuit on the plans, then yes, he would need to provide a plan modification to incorporate the door release.
INSP-Final Inspection1/24/20131/25/20131/25/2013AFAIL
DetailsTroy Cobbley
Need as-builts showing the deleted devices, test the interconnection with the fire sprinkler devices and the latest plan modification drawings.
Telephone call  1/25/2013 DONE
Tim w/ Crane Alarm called regarding plans. He said he can't find his city approved drawings. I let him know that I would take my set to Idaho Blueprint and he would be contacted to pay for them and pick them up. I explained that he would then need to bring his copy back to me to 'wet-stamp'.
Miscellaneous action  1/25/2013 DONE
Took our set of fire alarm plans to be copied
INSP-Final Inspection1/24/20131/24/20131/24/2013PCANC
DetailsTroy Cobbley
Canceled due to time constraints. Per agreement inspection is rescheduled for tomorrow morning at 7:30am. Also per tim he has not installed duct smoke detectors in some units that are missing. I asked him to bring as-built drawings showing the deleted devices. And that in the future if the devices are installed an additional permit will be required. The only other option is to install all devices. Tim Phone #: ###-####
Issue and Print Permit  12/27/2012 DONE
DetailsBarbara Stitt
Plan assigned to (Stephanie)12/20/2012 12/24/2012 DONE
DetailsStephanie L. Cobbley
Plan modification
Alarm Plan Check12/24/2012 12/24/2012 PASS
DetailsStephanie L. Cobbley
Plan modification approved with redlines and review comments.
PLANS TAKEN FRONT DESK ALARM  12/24/2012 DONE
Approved plan modification documents taken to permit technician for processing.
Inspection Record Card- Fire12/24/2012 12/24/2012 DONE
DetailsDarla L Downs
Permit Ready to Issue  12/24/2012  
Telephone call  12/24/2012  
12-24-12 called Crane Alarm Company left message permit ready and fee given ///dld
Issue and Print Permit  9/13/2012 DONE
DetailsBarbara Stitt
Plan assigned to (Stephanie)8/6/2012 8/15/2012 DONE
DetailsStephanie L. Cobbley
Telephone call  8/15/2012 DONE
Spoke to Mary Froemke at ECI to verify the location of the fire alarm control panel. Per the Boise Municipal code a remote annunciator is required. I asked her to please email me the data sheet for the annunciator the contractor will be installing. She said she would email it over.
Miscellaneous action  8/15/2012 DONE
Received requested data sheets
Miscellaneous action  8/15/2012 DONE
Emailed Mary at ECI requesting revised battery calculations due to the addition of the remote annunciator. She revised as requested and we discussed other redlines and comments. The FACP cannot be added to without prior approval from the plan reviewer. If battery sizes have to change due to field modifications, then a plan modification shall be required.
1st review completed  8/15/2012 PASS
Alarm Plan Check8/15/2012 8/15/2012 PASS
DetailsStephanie L. Cobbley
Approved with redlines and review comments.
PLANS TAKEN FRONT DESK ALARM  8/15/2012 DONE
Approved redlined plans taken to permit technician for processing.
Inspection Record Card- Fire8/15/2012 8/15/2012 DONE
DetailsDarla L Downs
Permit Ready to Issue  8/15/2012  
Telephone call  8/15/2012  
8-15-12 called Crane Alarm Service permit ready and fee given ///dld
Application received  8/6/2012  
Plan assigned to (Stephanie)1/29/2013    
DetailsStephanie L. Cobbley