Permit Information
Permit NumberFIR12-00433
StatusFinaled
Name R M E INC
Site Address 7500 W FAIRVIEW AVE
Project NameWestgate Shopping Center
Customer Number 
ePlanReviewNo
Description
12/11/12 Plan Modification (7 initiating devices affected): This plan modification is to provide a DSC wireless transmitter instead of the DACT for communications to central station monitoring, providing new addressable relay modules for each duct detector to perform HVAC shutdown, show the duct detectors using 24V instead of 120V from the HVAC units, and to provide an addressable monitor module for loss of power to the DSC.
8/16/12: This fire alarm permit is to replace the existing fire alarm panel with new. This permit scope of work includes removal of the existing fire alarm panel and all wiring, placement of the new panel in Electrical Room 107, smoke detector above the panel, pull station, duct detectors for HVAC monitoring/shutdown, and modules for monitoring the wet and dry sprinkler systems
Associated building permit: BLD11-02833
NOTE: a remote annunciator is not required under this permit.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection12/16/201512/17/201512/17/2015APASS
DetailsTroy Cobbley
Permit finaled
INSP-Final Inspection12/14/201512/16/201512/16/2015AFAIL
DetailsTroy Cobbley
Duct smoke detectors tested ok. FOr a final need as-builts submitted to lee for approval showing the different dialer and changed device counts and addresses. Also need to mount the map at the facp.
INSP-Conference10/26/201510/26/201510/26/2015PDONE
DetailsTroy Cobbley
Danielle with the propertry management company and I discussed getting the FIR12-00433 finaled prior to a final sign off on BLD15-03739. With Scott Arellano's permission the tenant can receive a temporary occupancy for 30 days while the contractors work towards getting the FIR permit finaled.
Issue permit  4/12/2013 DONE
Payment received via Govolutions
Fees Due Hold4/5/2013 4/12/2013 DONE
Details
INSP-Final Inspection4/2/20134/3/20134/3/2013AFAIL
DetailsTroy Cobbley
The first hvac unit tested did not shutdown upon activation of the duct smoke detector so no others were tested. The DSC communicator installed is not the model number in the submittal package and will need to be submitted for approval. As-builts and map do not match the actual installation with additional devices shown that have not been installed and addressing changes. The sprinkler systems devices did test ok and the correct signals were received at central station.
INSP-Alarm Testing3/21/20133/25/20133/25/2013PNR
DetailsForrest France
INSP-Alarm Testing3/13/20133/15/20133/15/2013AFAIL
DetailsTroy Cobbley
The approved "plan modification" drawings are not provided, pull station is too high, batteries are too small, sample tubes are too short (per silent knight tech support), need as-builts showing the deleted devices, per conversation only one of the hvac unit shuts down immediately upon detection of smoke. No actual testing was performed.
FIR-Aging Inspection2/5/20132/5/20132/13/2013 NR
DetailsTroy Cobbley
I left a voice mail for Anita at ESI requesting job status and then I spoke to Buster at RME and he stated that there is a monitoring problem that they are waiting for ESI to resolve. I will speak to Anita when she calls.
CHANGE STATUS TO (ISS)  12/12/2012 DONE
(F) Reprint permit  12/12/2012 DONE
Plan assigned to (Stephanie)12/3/2012 12/11/2012 DONE
DetailsStephanie L. Cobbley
Alarm Plan Check12/11/2012 12/11/2012 PASS
DetailsStephanie L. Cobbley
Plan modification approved with redlines and review comments.
PLANS TAKEN FRONT DESK ALARM  12/11/2012 DONE
Approved plan modification documents taken to the permit technician for processing.
Inspection Record Card- Fire12/11/2012 12/11/2012 DONE
DetailsDarla L Downs
Permit Ready to Issue  12/11/2012  
Telephone call  12/11/2012  
12-11-12 called r m e permit ready and fee given ///dld
Plan resubmittals received  12/3/2012 DONE
DetailsTisha Gallop
Plan Modification: received applicaiton and two copies of submittal folder and plans; routedt o SLC
Issue and Print Permit  8/28/2012 DONE
DetailsBarbara Stitt
Telephone call  8/17/2012 DONE
DetailsChristina Prado
Permit Ready to Issue  8/17/2012 DONE
DetailsChristina Prado
Inspection Record Card- Fire8/17/2012 8/17/2012 DONE
DetailsChristina Prado
Plan assigned to (Stephanie)8/8/2012 8/16/2012 DONE
DetailsStephanie L. Cobbley
Plan assigned to (Stephanie)8/8/2012 8/16/2012 DONE
DetailsStephanie L. Cobbley
Telephone call  8/16/2012 DONE
Spoke to Jeff Smith at E2CO to get clarification. I explained the permit indicates a new fire alarm panel to monitor a new sprinkler system in an existing building, however records indicate there is an existing sprinkler system. I asked him if they were actually replacing an existing fire alarm panel and he said he didn't know for sure that he would need to make some phone calls and get back to me.
Miscellaneous action  8/16/2012 DONE
Per a site visit by T. Cobbley, there is an existing Radionics fire alarm panel currently monitoring the sprinkler system in this space.
Telephone call  8/16/2012 DONE
Spoke with Jeff Smith with E2CO to let him know about the existing fire alarm control panel and ask if it is their intent to remove the existing panel or to network in to the existing panel. He stated it is the intent to remove the existing fire alarm panel and install a new fire alarm panel (indicated on the plans as being installed in Electrical Room 107).
1st review completed  8/16/2012 PASS
Alarm Plan Check8/16/2012 8/16/2012 PASS
DetailsStephanie L. Cobbley
Plans approved with review comments.
PLANS TAKEN FRONT DESK ALARM  8/16/2012 DONE
Approved plans taken to permit technicians for processing.
Application received  8/8/2012