Permit Information
Permit NumberFIR12-00535
StatusFinaled
Name SENTRY SECURITY SYSTEMS
Site Address 303 N ALLUMBAUGH ST
Project NameIntermountain Hospital
Customer Number 
ePlanReviewNo
Description
This quick permit is to add two new notification devices to a new smoking area. New devices are to be added to existing NACs. There are no written review comments. Approval is subject to field measurement of the EOL voltage drop. The voltage drop calculations are based on a 10% drop, therefore the minimum acceptable voltage is 21.6V with the AC power off. Any measurement below this voltage will be considered insufficient to run the NACs at the end of useful battery life of 20.4V (per UL 864, Standard for Control Units for Fire Signaling Systems). See NFPA 72 2010 Handbook 18.3.2.3 for further assistance with calculations.The installing contractor shall have available at final inspection a voltage meter and measure end of line voltages; witnessed by the field inspector. Associated building permit: BLD12-00101
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Miscellaneous action  2/14/2013 DONE
Plans taken to records for scanning
INSP-Final Inspection1/23/20131/23/20131/23/2013PPASS
DetailsTroy Cobbley
permit finaled
INSP-Alarm Testing11/26/201211/26/201211/26/2012PPASS
DetailsTroy Cobbley
Permit finaled
INSP-Alarm Testing10/8/201210/9/201210/9/2012AFAIL
DetailsTroy Cobbley
I verified the placement of the a/v's but the contractor did not want to test until the other FIR could be tested.
Telephone call  9/27/2012 DONE
Spoke to Deb at Power Plus asking for the status of the permit. She said she would check in to it and get back to me.
Issue and Print Permit  9/21/2012 DONE
Plan assigned to (Stephanie)9/19/2012 9/20/2012 DONE
DetailsStephanie L. Cobbley
Plan assigned to (Stephanie)9/19/2012 9/20/2012 DONE
DetailsStephanie L. Cobbley
1st review completed  9/20/2012 PASS
Alarm Plan Check9/20/2012 9/20/2012 PASS
DetailsStephanie L. Cobbley
Quick permit approved - no written review comments.
PLANS TAKEN FRONT DESK ALARM  9/20/2012 DONE
Approved quick permit plans taken to permit technician for processing.
Inspection Record Card- Fire9/20/2012 9/20/2012 DONE
DetailsDarla L Downs
Permit Ready to Issue  9/20/2012  
Telephone call  9/20/2012  
9-20-12 called Sentry Security Systems - Robert permit ready and fee given ///dld
Application received  9/19/2012