Information based on query as of Thursday, July 4, 2024.
Permit Information
Permit NumberFIR12-00634
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 800 W MAIN ST
Project Name8th & Main Tower - Standpipe
Customer NumberSTANDPIPE
ePlanReviewNo
Description
The fire sprinkler scope of work consists of two standpipes with associated outlets and drains. This review is not for the fire pump/header or any of the floor controls.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection12/17/201312/17/201312/18/2013PPASS
DetailsForrest France
INSP-Final Inspection12/12/201312/13/201312/13/2013APART
DetailsForrest France
Refer to fire plan review notes item # 7 regarding isolation valves. Also noted missing caps at several locations.
INSP-Final Inspection11/27/201312/2/201312/3/2013APART
DetailsForrest France
Missing valve caps at several locations.
INSP-Final Inspection11/19/201311/22/201311/26/2013ANR
DetailsForrest France
Mike B is the contact. Thanks Phone #: ###-#### >> Inspection requested via web by Stan Beus
INSP-Sprinkler Rough-in/Hydro7/30/20137/31/20137/31/2013APART
DetailsForrest France
OH hydrostatic test of both standpipes completed satisfactory.
FIR-Aging Inspection6/28/20136/28/20136/28/2013 DONE
DetailsForrest France
Site work in progress
INSP-Sprinkler Rough-in/Hydro3/27/20133/29/20133/29/2013PPART
DetailsForrest France
For OH hydrostatic test up to the 10th floor.
INSP-Sprinkler Rough-in3/5/20133/5/20133/5/2013APART
DetailsForrest France
Standpipe to within one floor of secured decking is installed.
INSP-Sprinkler Rough-in2/15/20132/19/20132/21/2013APART
DetailsForrest France
Partial rough in for standpipe. Mike B is the contact. Thanks Phone #: ###-#### >> Inspection requested via web by Stan Beus
Miscellaneous action  2/15/2013 DONE
Email from Jim Darr @ Shilo Automatic Sprinkler, Inc.

We have been fabricating and installing the standpipe in both stairs of the 8th and Main project at the same time as the rough-in of the floors. The stand pipe is always installed so that is less than 40 feet from the highest point of the building. We were unaware that we needed to call in for a partial standpipe inspection. I have brought this issue up with our field foreman on this project and he will call in a schedule a partial rough in for the standpipe system.

Jim Darr, C.E.T.
Design Technician
Shilo Automatic Sprinkler, Inc.
1224 11th Ave. North
Nampa, Idaho 83687
Phnoe ###-####
Fax ###-####
Issue and Print Permit  11/14/2012 DONE
DetailsTisha Gallop
Sprinkler Plan Check11/13/2012 11/13/2012 PASS
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
PLANS/APPL TAKEN TO FRONT DESK  11/13/2012 DONE
DetailsTim Frost
Telephone call  11/13/2012 DONE
DetailsChristina Prado
called Cameron to advise permit is ready and gave fees due
Inspection Record Card- Fire11/13/2012 11/13/2012 DONE
DetailsChristina Prado
Permit Ready to Issue  11/13/2012 DONE
DetailsChristina Prado
Plan assigned to (Tim)10/31/2012 11/13/2012 DONE
DetailsTim Frost
Plan resubmittals received  11/7/2012 DONE
DetailsTisha Gallop
received three copies of application, submittal folder and plans; routed to Fire
Sprinkler Plan Check11/2/2012 11/2/2012 FAIL
DetailsTim Frost
Please, see attached comments.
There are NO annotations on the plans.
1st review completed  11/2/2012 FAIL
DetailsTim Frost
Miscellaneous action  11/2/2012 DONE
DetailsTim Frost
Emailed review to contractor
Telephone call  11/2/2012 DONE
DetailsTisha Gallop
called Jim and told him denied plans ready for pick up
Application received  10/31/2012  
Case Summary  10/31/2012 DONE
DetailsBarbara Stitt
Early Start  10/31/2012 PASS
See attached