Permit Information
Permit NumberFIR13-00654
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 601 W FRONT ST
Project NamePanda Express T.I.
Customer Number 
ePlanReviewYes
Description
The fire sprinkler scope of work consists of adding, plugging and relocating sprinklers to accommodate new wall and ceiling configuration.

*** 11-14-13 PLAN MODIFICATION TO INCLUDE: KITCHEN & RESTROOM LAYOUT CHANGES DUE TO NEW FIRE RISER LOCATION; ADDED ADDITIONAL LIGHTING FIXTURE IN EACH RESTROOM ** SRZ. To build-out for the first time a 2,002 square foot tenant space for use by a restaurant in an existing shell building constructed under BLD13-00730. Work to include: new concrete slab floor; construction of interior nonbearing walls to create: Dining room, kitchen, kitchen prep. room, serving area, and two fully accessible restrooms for men/women; install a gypsum ceiling; install a walk-in cooler and walk-in freezer; related interior finishes in compliance with chapter 8 of the 2009 IBC; new light fixtures and plumbing fixtures; install a new HVAC unit and duct work; intstall new Type I hoods; and relocate an existing door and modify an existing storefront at the South elevation. All work per the approved plans, red-lined comments, and conditions of all reviewing agencies for this project. Energy code compliance for the envelope was part of the SHELL permit. A Certificate of Occupancy with the occupant load total is required to be obtained after all work has been inspected and approved and prior to tenant occupying this space. NOTE: This building is fully fire sprinklered and has an approved alarm system. ANY ALTERATIONS TO THE SPRINKLER SYSTEM WILL REQUIRE A SEPARATE PERMIT, and shall be installed per NFPA #13 as regulated by the fire department. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection12/19/201312/20/201312/20/2013PPASS
DetailsForrest France
Fire sprinkler permit work passed final walkthrough.
INSP-Sprinkler Rough-in12/5/201312/6/201312/18/2013PPART
DetailsForrest France
INSP-Sprinkler Rough-in12/17/201312/18/201312/18/2013APART
DetailsForrest France
Overhead work at the grid and sheetrock ceilings approved for cover. Need to provide walls to the deck or a drop ceiling with pendent coverage at the fire riser room.
Plan assigned to (Tim)11/18/2013 11/18/2013 DONE
DetailsTim Frost
Sprinkler Plan Check11/18/2013 11/18/2013 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  11/18/2013 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  11/18/2013 DONE
DetailsTim Frost
Permit Ready to Issue  11/18/2013 DONE
DetailsChristina Prado
Issue and Print Permit  11/18/2013 DONE
DetailsChristina Prado
Inspection Record Card- Fire11/18/2013 11/18/2013 DONE
DetailsChristina Prado
Application received  11/15/2013 DONE
Application submitted via PDS Online on Nov 15 2013 10:15AM