Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberFIR14-00406
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 6760 W IRVING ST
Project NameAberdeen 4-Plex #6760 UG Line
Customer NumberUDG ONLY
ePlanReviewYes
Description
Quick Permit

A new dedicated fire protection underground 2"x120'+- poly pipe

L14B2 - 6760 Irving - (Bldg 6) To construct a new 3,909 sq. ft., two story, Four unit, apartment building. Each unit has two bedrooms, and two bathrooms. The 1st story units are required to be Type 'B' units. All units share a common path of egress into and through a 1-hour rated exit corridor with 20 minute fire-resistive, listed, labeled, self-closing door assemblies from the dwelling units into the corridor. All construction per the approved plans, attached plan review report, and all other reviewing agencies approvals. One hour fire-partitions and one hour horizontal assemblies are required between dwelling units. This building is required to be fire sprinklered. The fire sprinkler system shall be per NFPA 13R as regulated by the fire department. DRH13-00276 & CUP13-00017 Per Planning and Zoning. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection11/24/201511/25/201511/25/2015APASS
DetailsTroy Cobbley
Permit finaled
INSP-Sprinkler Rough-in/Hydro9/19/20149/19/20149/19/2014PPASS
DetailsTroy Cobbley
as per Troy Cobbley passed-ok to put in system
INSP-Final Inspection9/12/20149/15/20149/12/2014PCANC
DetailsTroy Cobbley
Mike is the contact. Thanks Phone #: ###-#### >> Inspection requested via web by Stan Beus Inspection cancelled from web by: Stan Beus
INSP-Supply line flush8/15/20148/18/20148/18/2014PPASS
DetailsTroy Cobbley
Underground flush passed
INSP-Sprinkler Rough-in6/30/20146/30/20146/30/2014PPASS
DetailsTroy Cobbley
The underground supply piping is ok to cover
Permit Ready to Issue  6/26/2014 DONE
DetailsCandy A. Nichols
Issue and Print Permit  6/26/2014 DONE
DetailsCandy A. Nichols
Inspection Record Card- Fire6/26/2014 6/26/2014 DONE
DetailsCandy A. Nichols
Plan assigned to (Tim)6/25/2014 6/25/2014 DONE
DetailsTim Frost
Sprinkler Plan Check6/25/2014 6/25/2014 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  6/25/2014 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  6/25/2014 DONE
DetailsTim Frost
Application received  6/21/2014 DONE
Application submitted via PDS Online on Jun 21 2014 7:39AM