Permit NumberFIR14-00937
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 1109 W MAIN ST Unit: 360
Project NameVANILLA TI #5 STE 360
Customer Number 
ePlanReviewYes
Description
[THE OWYHEE SHELL TI - SUITE 360]- Quick Permit
RECONFIGURE THE HEADS AND ARM OVERS IN THE AREA OF WORK. THE NEW HEAD LAYOUT IS TO ACCOMMODATE THE REMODEL AND COMPLY WITH NFPA 13 STANDARDS. THE EXISTING 2 1/2" MAIN WILL STAY IN PLACE WITH EXISTING EARTHQUAKE BRACING AND THE MAIN AND LINES WILL BE TAPPED FOR NEW LINE AND HEAD LOCATIONS.

The fire sprinkler system is used for area, height, and story increase. This is one of four permits attached to the drawings filed under permit BLD14-03334 in ePlanReview. To construct a 199 square foot shell office tenant space located at the East side of the 3rd story of the Owyhee Place historic building. The shell and core upgrade work was done under permit BLD13-00938. A non-rated corridor was constructed to connect the exit stairways under permit BLD14-01091. Work is to include interior nonbearing walls, an interior door with a glass sidelight, suspended acoustical ceilings, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 (including quick-response heads where not provided) and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. A fire sprinkler permit shall be obtained prior to beginning any modification or installation work on such systems. A fire alarm permit shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection2/24/20152/24/20152/24/2015APASS
DetailsForrest France
Fire sprinkler permit finaled.
INSP-Sprinkler Rough-in1/28/20151/28/20151/28/2015PPART
DetailsForrest France
Overhead fire sprinkler work approved for cover at the drop ceiling.
Permit Ready to Issue  1/5/2015 DONE
Issue and Print Permit  1/5/2015 DONE
Inspection Record Card- Fire1/5/2015 1/5/2015 DONE
DetailsKristal Soland
Intake Approval  12/31/2014 PASS
Plan assigned to (Tim)12/31/2014 12/31/2014 DONE
DetailsTim Frost
Sprinkler Plan Check12/31/2014 12/31/2014 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  12/31/2014 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  12/31/2014 DONE
DetailsTim Frost
Application received  12/30/2014 DONE
Application submitted via PDS Online on Dec 30 2014 8:31AM