INSP-Final Inspection | 10/1/2015 | 10/2/2015 | 10/2/2015 | A | PASS |
Troy Cobbley
|
|
|
Permit finaled
|
INSP-Final Inspection | 9/30/2015 | 9/30/2015 | 9/30/2015 | P | PART |
Troy Cobbley
|
|
|
A temporary is being given until the sprinkler protection is provided under the cooler doors. The forward flush inspection passed
|
Sprinkler Plan Check | 9/25/2015 | | 9/25/2015 | | PASS |
Tim Frost
|
|
|
Please, see attached comments.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 9/25/2015 | | DONE |
Tim Frost
|
|
|
|
Permit Ready to Issue | | | 9/25/2015 | | DONE |
|
|
|
DO NOT RE-ISSUE No fees per Tim F
|
CHANGE STATUS TO (ISS) | | | 9/25/2015 | | |
|
|
|
|
Sprinkler Plan Check | 9/22/2015 | | 9/22/2015 | | FAIL |
Tim Frost
|
|
|
|
Miscellaneous action | | | 9/22/2015 | | DONE |
Tim Frost
|
|
|
Emailed contractor in regards to failed review.
|
INSP-Final Inspection | 9/3/2015 | 9/3/2015 | 9/3/2015 | P | FAIL |
Jim Page
|
|
|
No sprinklers covering under the two overhead doors located inside of the cooler section, needs sprinkler coverage. No ball drip on FDC. Need specifications on air compressor installed on dry system to see if it meets the requirements of 7.2.6.6.2-air compressor supplying dry pipe system has a capacity of less the 5.5 cubic feet at 10 psi, currently no air maintenance on dry system and contractor is referencing mentioned code from NFPA13.
|
Plan assigned to (Tim) | 9/3/2015 | | 9/3/2015 | | DONE |
Tim Frost
|
|
|
|
INSP-Sprinkler Rough-in/Hydro | 8/13/2015 | 8/13/2015 | 8/13/2015 | P | PASS |
Troy Cobbley
|
|
|
Overhead hydro test passed
|
INSP-Supply line flush | 8/11/2015 | 8/11/2015 | 8/11/2015 | P | PASS |
Troy Cobbley
|
|
|
Underground flush passed
|
INSP-Sprinkler Rough-in | 7/22/2015 | 7/22/2015 | 7/22/2015 | P | PASS |
Troy Cobbley
|
|
|
Rough-in for the first and second floor office areas passed. Resubmittals will be needed due to routing changes for the main and extended coverage sidewalls. Also will need protection provided under the tanks.
|
Permit Ready to Issue | | | 6/23/2015 | | DONE |
|
|
|
|
Issue and Print Permit | | | 6/23/2015 | | DONE |
|
|
|
|
Inspection Record Card- Fire | 6/23/2015 | | 6/23/2015 | | DONE |
Christina Prado
|
|
|
|
Plan assigned to (Tim) | 6/16/2015 | | 6/16/2015 | | DONE |
Tim Frost
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/16/2015 | | DONE |
|
|
|
|
Sprinkler Plan Check | 5/19/2015 | | 5/19/2015 | | PASS |
Tim Frost
|
|
|
Please, see attached comments.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/19/2015 | | DONE |
Tim Frost
|
|
|
|
Sprinkler Plan Check | 5/7/2015 | | 5/7/2015 | | FAIL |
Tim Frost
|
|
|
|
Miscellaneous action | | | 5/7/2015 | | DONE |
Tim Frost
|
|
|
Emailed contractor in regards to failed review.
|
Intake Approval | | | 3/13/2015 | | PASS |
|
|
|
|
Plan assigned to (Tim) | 3/13/2015 | | 3/13/2015 | | DONE |
Tim Frost
|
|
|
|
Sprinkler Plan Check | 3/13/2015 | | 3/13/2015 | | FAIL |
Tim Frost
|
|
|
|
1st review completed | | | 3/13/2015 | | FAIL |
Tim Frost
|
|
|
|
Miscellaneous action | | | 3/13/2015 | | DONE |
Tim Frost
|
|
|
Emailed contractor in regards to failed review.
|
Application received | | | 3/5/2015 | | DONE |
|
|
|
Application submitted via PDS Online on Mar 5 2015 8:19AM
|