Case Summary | | | 12/9/2015 | | DONE |
|
|
|
|
INSP-Final Inspection | 9/2/2015 | 9/3/2015 | 9/3/2015 | A | PASS |
Jim Page
|
|
|
Final fire alarm inspection passed/complete
|
CHANGE STATUS TO (ISS) | | | 9/2/2015 | | DONE |
|
|
|
plan mod fees paid
|
Plan resubmittals received | | | 9/1/2015 | | DONE |
|
|
|
|
Alarm Plan Check | 9/1/2015 | | 9/1/2015 | | PASS |
Lee G Meredith
|
|
|
|
PLANS TAKEN FRONT DESK ALARM | | | 9/1/2015 | | DONE |
|
|
|
Resubmittal of plan mod 2 approved with review comments.
|
Plan resubmittals received | | | 8/28/2015 | | DONE |
|
|
|
Plan modification recieved. Numerous wall strobes moved to ceiling. Changes on sprinkler monitoring and elevator status light.
|
CHANGE STATUS TO (REV) | | | 8/28/2015 | | DONE |
|
|
|
|
Alarm Plan Check | 8/28/2015 | | 8/28/2015 | | FAIL |
Lee G Meredith
|
|
|
See Plan Mod 2 review comments.
|
INSP-Final Inspection | 8/26/2015 | 8/26/2015 | 8/26/2015 | P | FAIL |
Troy Cobbley
|
|
|
The only items test today was verifying the facp and nac panels, phone lines, elevator recall and fire sprinkler flow and tamper switches. I noted that the elevator power needs to be monitored but hat functions can remain as-is, all of the wall mount strobes are mounted too low, many of the strobes are overspaced, additional notification devices are required on the third floor in the areas that are to remain occupied. As-builts with these corrections and corrected floor plan layout will be required. I did not inspect any of the first floor or basement today.
|
Telephone call | | | 8/26/2015 | | DONE |
|
|
|
Rob Ahten call to say they found a sprinkler head in the elevator shaft and added a smoke and heat there that ware tied to recall and shunt. I told him that we would not require a resubmittal but would require as built drawings sent in for archiving. Called Troy to let him know.
|
Plan resubmittals received | | | 6/17/2015 | | DONE |
|
|
|
|
Alarm Plan Check | 6/17/2015 | | 6/17/2015 | | PASS |
Lee G Meredith
|
|
|
|
PLANS TAKEN FRONT DESK ALARM | | | 6/17/2015 | | DONE |
|
|
|
Resubmittal of plan mod approved with review comments. Projectdox updated.
|
CHANGE STATUS TO (ISS) | | | 6/17/2015 | | DONE |
|
|
|
|
Plan resubmittals received | | | 6/16/2015 | | DONE |
|
|
|
Plan modification to replace the existing fire alarm panel and related components.
|
CHANGE STATUS TO (REV) | | | 6/16/2015 | | DONE |
|
|
|
Changed to review status for plan modification.
|
1st review completed | | | 6/16/2015 | | FAIL |
|
|
|
See 6-16-15 review comments.
|
Telephone call | | | 6/15/2015 | | DONE |
|
|
|
Jonathan call to request the work flow be reopened. Owner has decided to add panel replacement to the scope of work.
|
Permit Ready to Issue | | | 3/12/2015 | | DONE |
|
|
|
|
Issue and Print Permit | | | 3/12/2015 | | DONE |
|
|
|
|
Inspection Record Card- Fire | 3/12/2015 | | 3/12/2015 | | DONE |
Christina Prado
|
|
|
|
Plan assigned to (Lee) | 3/11/2015 | | 3/11/2015 | | DONE |
Lee G Meredith
|
|
|
|
1st review completed | | | 3/11/2015 | | PASS |
|
|
|
|
Alarm Plan Check | 3/11/2015 | | 3/11/2015 | | PASS |
Lee G Meredith
|
|
|
|
PLANS TAKEN FRONT DESK ALARM | | | 3/11/2015 | | DONE |
|
|
|
Plans approved with review comments. Projectdox updated.
|
Application received | | | 3/10/2015 | | DONE |
|
|
|
Application submitted via PDS Online on Mar 10 2015 10:39AM
|