Permit Information
Permit NumberFIR15-00253
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 3100 S VISTA AVE
Project NameICRMP 2ND FLOOR REMODEL
Customer Number 
ePlanReviewYes
Description
[ICRMP 2nd Floor Remodel]
The fire sprinkler scope of work consists of remodeling the second floor.

(I.C.R.M.P. - 2ND STORY REMODEL) (1-29-15 PLAN MODIFICATION TO DELETE THE PROPOSED NEW ENERGY RECOVERY UNIT ON THE 2ND STORY THAT WAS GOING TO SERVE A PORTION OF THE 2ND STORY AND TO PROVIDE A NEW ENERGY RECOVERY UNIT IN THE BASEMENT THAT WILL SERVE THE ENTIRE BUILDING INCLUDING THE ENTIRE 2ND STORY. WORK IS TO INCLUDE INSTALLING A NEW ENERGY RECOVERY UNIT AND REBALANCING THE SYSTEM.) Fire sprinkler system is used for story increase. To remodel the 10,683 square foot 2nd story of an existing 3 story building for an office tenant. The office tenant space will include a 1,310 square foot conference room. Work is to include interior nonbearing walls, interior doors, interior windows, suspended acoustical ceilings, gypsum board soffits, millwork, and finishes. New finishes will be installed within the existing restrooms. The restrooms are required to be accessible to the disabled. A new energy recovery unit will be installed. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system, including quick-response heads, is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection8/24/20158/25/20158/25/2015APASS
DetailsTroy Cobbley
Permit finaled
INSP-Sprinkler Rough-in7/1/20157/2/20157/2/2015APASS
DetailsTroy Cobbley
Rough-in passed. Piping can be covered.
Intake Approval  4/29/2015 PASS
Plan assigned to (Tim)4/29/2015 4/29/2015 DONE
DetailsTim Frost
Sprinkler Plan Check4/29/2015 4/29/2015 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  4/29/2015 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  4/29/2015 DONE
DetailsTim Frost
Permit Ready to Issue  4/29/2015 DONE
Issue and Print Permit  4/29/2015 DONE
Inspection Record Card- Fire4/29/2015 4/29/2015 DONE
DetailsCandy A. Nichols
Application received  4/24/2015 DONE
Application submitted via PDS Online on Apr 24 2015 1:10PM