Permit NumberFIR15-00591
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 13901 W WAINWRIGHT DR
Project NameAlliance Soft Tissue T.I.
Customer Number 
ePlanReviewYes
Description
[Sentry Management - Suite 150] - Quick Permit
Shilo will relocate 4 pendents and replace with new and add 3 new pendents to accommodate the new ceiling and wall layout.

Contractor’s Note:
The building permit has not been issued at this time. The building department may determine that changes are required to the building plans in order to meet code. The changes may affect the sprinkler system. The sprinkler contractor will be obligated to make all necessary changes that may be required. Therefore, if the sprinkler contractor chooses to proceed without an issued building permit, they will do so on their own cognizance. This note does not constitute an early start agreement.



[Sentry Management - Suite 150]
The fire sprinkler scope of work consists of adding, plugging and relocating sprinklers to accommodate new wall and ceiling configuration.

(SENTRY MANAGEMENT- SUITE #150) Permit is to remodel existing 2,602 sq. ft. office space suite #150 and combining with adjacent 2,138 sq. ft. office tenant space suite #120 to make a total 4,778 sq. ft. tenant space, this permit is approved contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls and construction of select interior non-bearing walls to create twelve new offices, a break room with sink and a new conference room, mechanical duct work, relocation of existing lighting fixtures, and interior finishes in compliance with chapter 8 of the 2012 IBC. This building is fully fire sprinklered any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection9/30/20159/30/20159/30/2015PPASS
DetailsTroy Cobbley
Permit finaled
INSP-Sprinkler Rough-in9/28/20159/29/20159/30/2015AFAIL
DetailsTroy Cobbley
Installation for the most part is passed. I have concerns with a piping arrangement that does not match plan. Cam is going to discuss with Tim Frost.
Intake Approval  8/24/2015 PASS
Plan assigned to (Tim)8/24/2015 8/24/2015 DONE
DetailsTim Frost
Sprinkler Plan Check8/24/2015 8/24/2015 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  8/24/2015 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  8/24/2015 DONE
DetailsTim Frost
Permit Ready to Issue  8/24/2015 DONE
Issue and Print Permit  8/24/2015 DONE
Inspection Record Card- Fire8/24/2015 8/24/2015 DONE
DetailsKristal Soland
Application received  8/23/2015 DONE
Application submitted via PDS Online on Aug 23 2015 4:55PM