Permit Information
Permit NumberFIR15-00619
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 7960 W NORTHVIEW ST
Project NameST MARKS PRE-SCHOOL TI
Customer Number 
ePlanReviewYes
Description
[St. Mark's Preschool - South west Corner of Building] - Quick Permit
TVFP WILL REPLACE 6 HEADS IN THE AREA OF WORK TO QUICK RESPONSE. EXISTING LINES AND MAINS WILL STAY IN PLACE. THE NEW HEAD LAYOUT IS TO ACCOMMODATE THE REMODEL AND COMPLY WITH NFPA 13 STANDARDS. EXISTING EQ BRACING AND HANGERS WILL STAY IN PLACE.

ST. MARK’S PRESCHOOL – SOUTHWEST CORNER OF BUILDING) The fire sprinkler system is used for building area increase. To convert two Church classrooms having a total floor area of about 853 square feet (603 square feet and 250 square feet) to a full-time functioning daycare/preschool within an existing Church. Children less than 2.5 years of age are not allowed to be cared for within the daycare/preschool area since neither of the rooms has a door that opens directly to the outside. Smoke detectors are required in rooms used for sleeping. A carbon monoxide detector is required within each childcare room. The number of children is limited by CUP14-00022 to 24 maximum. Work is to include interior nonbearing walls, 2 egress doors with panic hardware, and exit signs. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such system. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection9/2/20159/2/20159/2/2015PPASS
DetailsTroy Cobbley
permit finaled
INSP-Sprinkler Rough-in9/2/20159/2/20159/2/2015PPASS
DetailsTroy Cobbley
Please Call Lonnie Phone #: ###-#### Inspection requested via web by Nathan Stenquist
Intake Approval  9/2/2015 PASS
Plan assigned to (Tim)9/2/2015 9/2/2015 DONE
DetailsTim Frost
Sprinkler Plan Check9/2/2015 9/2/2015 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  9/2/2015 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  9/2/2015 DONE
DetailsTim Frost
Permit Ready to Issue  9/2/2015 DONE
Issue and Print Permit  9/2/2015 DONE
Inspection Record Card- Fire9/2/2015 9/2/2015 DONE
DetailsKristal Soland
Application received  9/1/2015 DONE
Application submitted via PDS Online on Sep 1 2015 10:10AM