Permit Information
Permit NumberFIR16-00361
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 10436 W OVERLAND RD
Project NameNW PETS TI
Customer Number 
ePlanReviewYes
Description
[Northwest Pets TI] - Quick Permit
RELOCATE 16 AND ADD 3 SPRINKLER HEADS IN THE AREA OF WORK. THE LINES WILL BE UPSIZED TO ACCOMMODATE THE ADDED HEADS. DEMO AND PLUG EXISTING SSP DROPS THROUGHOUT THE TI SPACE. EXISTING CONSTRUCTION IS OPEN WEB BAR JOISTS WITH WOOD TOP AND BOTTOM CORDS. DECK HEIGHT IS 15'-0".

** (NORTHWEST PETS) ** Permit is to remodel an existing 4,108 sq. ft. tenant retail space. Approval is contingent upon adhering to the approved plans on file. Work to include: Removal of select interior nonbearing walls, removal of select door and frame, removal of existing restroom, removal of suspended acoustic ceiling, removal of light fixtures, construction of select interior nonbearing walls to create (2) dog wash areas, employee break room with a new sink, a utility area with a new mop sink, a smaller stock room, a hallway and (2) ADA compliant accessible restrooms, new select millwork, new light fixtures, electrical work, mechanical work, plumbing work and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection7/20/20167/21/20167/21/2016APASS
DetailsTroy Cobbley
Permit finaled
INSP-Sprinkler Rough-in/Hydro6/7/20166/7/20166/7/2016PPASS
DetailsTroy Cobbley
Piping above hardlids is ok to cover.
Intake Approval  6/2/2016 PASS
Plan assigned to (Tim)6/2/2016 6/2/2016 DONE
DetailsTim Frost
Sprinkler Plan Check6/2/2016 6/2/2016 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  6/2/2016 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  6/2/2016 DONE
DetailsTim Frost
Permit Ready to Issue  6/2/2016 DONE
Issue and Print Permit  6/2/2016 DONE
Inspection Record Card- Fire6/2/2016 6/2/2016 DONE
DetailsCandy A. Nichols
Application received  6/1/2016 DONE
Application submitted via PDS Online on Jun 1 2016 10:08AM