Permit Information
Permit NumberFIR16-00548
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 246 N 8TH ST
Project NameRED FEATHER LOUNGE TI
Customer Number 
ePlanReviewYes
Description
[Red Feather Lounge] - Quick Permit
INSTALL NEW PENDENT AND UPRIGHT SPRINKLER HEADS TO THE NEW WALL ANC CEILING LAYOUT.

[BLD15-03403] - The fire sprinkler system is used to substitute for 1-hr fire-resistance-rated construction of the building. To prepare a 598 square foot basement room for occupancy as a drinking/dining assembly room for the public. It was approved previously for storage. A 407 square foot storage area and egress hallway from the assembly room will also be finished under this permit. Work is to include millwork and finishes. Mechanical work to provide adequate ventilation will be done in conjunction with the work approved under this permit. Shell work to create a code compliant egress path from the 598 square foot basement assembly room leading to an existing enclosed 1-hr exit stairway from the basement was done under permit BLD15-03345. Structural work done under that permit included new beams, lengthening an existing beam, placing concrete footings, placing concrete retaining walls, and installing new steel lintels with steel jambs at new openings in existing masonry bearing walls. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection12/5/201612/5/201612/5/2016APASS
DetailsJim Page
Final fire sprinkler inspection passed/complete
INSP-Sprinkler Rough-in/Hydro10/10/201610/10/201610/10/2016APASS
DetailsJim Page
Rough to cover inspection for overhead fire sprinkler piping in area of work complete, overhead fire sprinkler piping in area of work approved for cover.
Sprinkler Plan Check8/22/2016 8/22/2016 PASS
DetailsTim Frost
Please, see attached comments.
PLANS/APPL TAKEN TO FRONT DESK  8/22/2016 DONE
DetailsTim Frost
Permit Ready to Issue  8/22/2016 DONE
Issue and Print Permit  8/22/2016 DONE
Inspection Record Card- Fire8/22/2016 8/22/2016 DONE
DetailsCandy A. Nichols
Intake Approval  8/19/2016 PASS
Plan assigned to (Tim)8/19/2016 8/19/2016 DONE
DetailsTim Frost
Application received  8/18/2016 DONE
Application submitted via PDS Online on Aug 18 2016 10:27AM