Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberFIR16-00677
StatusFinaled
Name THORPE FIRE SPRINKLER SYSTEMS
Site Address 135 S BROADWAY AVE
Project NameSprint Store TI
Customer Number 
ePlanReviewYes
Description
[Sprint] - Quick Permit
Install 15 new pendent sprinklers on the existing system in this shell condition tenant space to account for new dropped ceilings.

[BLD16-03715] - Permit is to remodel 1,630 sq. ft. vacant tenant space created under BLD15-01964. Approval contingent upon adhering to the approved plans on file. Work to include: construction of interior nonbearing walls to create a sales area, a break room and a hallway, new door/door frames, millwork, new accessible Hi/Low drinking fountain, adding vertical grab bar in the existing accessible restroom and relocate sink to make restroom accessible to the disabled, new acoustic ceiling, new light fixtures, Plumbing work, electrical work, mechanical work and interior finishes in compliance with Ch. 8 of the 2012 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection11/16/201611/16/201611/16/2016PPASS
DetailsJim Page
Final fire sprinkler inspection passed/complete
INSP-Sprinkler Rough-in11/16/201611/16/201611/16/2016PPASS
DetailsJim Page
Rough to cover inspection for overhead fire sprinkler piping complete, overhead fire sprinkler piping approved for cover.
INSP-Sprinkler Rough-in11/14/201611/15/201611/15/2016AFAIL
DetailsTroy Cobbley
The pendant heads in the Sales area exceed 130 sq. ft. for max. coverage.
Intake Approval  10/25/2016 PASS
Plan assigned to (Tim)10/25/2016 10/25/2016 DONE
DetailsTim Frost
Sprinkler Plan Check10/25/2016 10/25/2016 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  10/25/2016 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  10/25/2016 DONE
DetailsTim Frost
Permit Ready to Issue  10/25/2016 DONE
Issue and Print Permit  10/25/2016 DONE
Inspection Record Card- Fire10/25/2016 10/25/2016 DONE
DetailsBrittany Hill
Application received  10/24/2016 DONE
Application submitted via PDS Online on Oct 24 2016 7:14PM