Permit NumberFIR17-00130
StatusFinaled
Name THORPE FIRE SPRINKLER SYSTEMS
Site Address 7364 W SAXTON DR
Project NameKensington Apts Bldg D UG
Customer NumberUDG ONLY
ePlanReviewYes
Description
[Kensington Apartmentes Building D - UDG Only] - Quick Permit
Install a 2" fire service line to the base of riser location at the building D fire riser room. Also install the overhead system, to be submitted on a separate permit.

[BLD15-01121] - The drawings are filed under BLD15-01118 in ePlanReview. The NFPA 13-R fire sprinkler system is used for occupancy and for story increase. To construct a 44,518 square foot four story apartment building (11,390 sq. ft. 1st story with two 3.c units, two 3.b units, three 2.c units, and one 2.g unit, 11,390 sq. ft. 2nd story with four 3.b units, three 2.c units, and one 2.g unit, 11,390 sq. ft. 3rd story with four 3.b units, three 2.c units, and one 2.g unit, 11,390 sq. ft. 4th story with four 2.d units, three 2.c units, and one 2.g unit) An elevator is provided in this building that serves all stories. All units in this building are required to comply as Type B dwelling units. Of those Type B dwelling units, 2 will also comply as Type A units. Work is to include concrete footings, concrete foundations, concrete slabs on grade, wood stud bearing walls, wood stud shear walls, fiberglass shingles, fiber-cement board siding, manufactured stone veneer, a 2-hr elevator shaft, 1-hr dwelling unit separations, .5-hr minimum fire-resistance-rated corridors with 20 minute smoke- and draft-control doors, exterior exit stairways fire rated like the corridors, steel stairways with concrete treads, interior nonbearing walls, millwork, and finishes. Special Inspection is required for soils and for concrete. The roof truss design is a deferred submittal item. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13-R and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection12/20/201712/20/201712/20/2017PPASS
DetailsTroy Cobbley
Permit finaled

Call Jake before heading out Phone #: ###-#### Inspection requested via web by Anthony Minichiello
INSP-Final Inspection12/19/201712/19/201712/19/2017PCANC
DetailsJim Page
Call Jake before heading out Phone #: ###-#### >> Inspection requested via web by Anthony Minichiello Inspection cancelled from web by: Anthony Minichiello
INSP-Supply line flush6/14/20176/15/20176/15/2017APASS
DetailsTroy Cobbley
Underground flush passed
INSP-Sprinkler Rough-in/Hydro3/22/20173/22/20173/22/2017PPASS
DetailsJim Page
Underground hydrostatic test complete
INSP-Supply line flush3/21/20173/22/20173/22/2017PCANC
DetailsJim Page
Incorrect inspection request, request is for an underground hydro, this request cancelled and the correct request generated.
INSP-Supply line flush3/21/20173/23/20173/21/2017PCANC
DetailsJim Page
Underground rough/hydro. Call Jake when heading out, thanks! Phone #: ###-#### >> Inspection requested via web by Anthony Minichiello Inspection cancelled from web by: Anthony Minichiello
Intake Approval  3/21/2017 PASS
Plan assigned to (Tim)3/21/2017 3/21/2017 DONE
DetailsTim Frost
Sprinkler Plan Check3/21/2017 3/21/2017 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  3/21/2017 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  3/21/2017 DONE
DetailsTim Frost
Permit Ready to Issue  3/21/2017 DONE
DetailsChristina Prado
Issue and Print Permit  3/21/2017 DONE
DetailsChristina Prado
Inspection Record Card- Fire3/21/2017 3/21/2017 DONE
DetailsChristina Prado
Application received  3/20/2017 DONE
Application submitted via PDS Online on Mar 20 2017 4:04PM