Permit Information
Permit NumberFIR18-00367
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 1101 W RIVER ST Unit: 120
Project NameT.I. IN SUITES #120 & #110
Customer Number 
ePlanReviewYes
Description
[TI for Suites #110 & #120 - Sawtooth Law Suite #110] - Quick Permit
RELOCATE EXISTING QUICK RESPONSE HEADS TO NEW CEILING AND WALL LAYOUT

[BLD18-01104]
This building is fully fire sprinklered for one-hour substitution. Permit is to remodel an existing 2,455 sq. ft. tenant space by acquiring additional square footage from the existing adjacent tenant space to create a new tenant space that is 3,172 sq. ft. and reduce the existing 1,954 sq. ft. adjacent tenant space to 1,232 sq. ft. which is to be occupied by Golden Eagle under BLD18-01172. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frames and relocate, removal of select interior windows and relocate, removal of select millwork, construction of select new interior nonbearing walls to demise tenant spaces, to create (4) offices, select new interior window, relocate existing light fixtures, electrical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection5/30/20185/30/20185/30/2018APASS
DetailsJim Page
Final fire sprinkler inspection for area of work complete.
INSP-Sprinkler Rough-in5/14/20185/14/20185/14/2018PPASS
DetailsJim Page
Rough to cover inspection for overhead fire sprinkler piping in area of work complete, approved for cover.

troy nelson is our foreman Phone #: ###-#### Inspection requested via web by Brad Bettencourt
Issue and Print Permit  5/8/2018 DONE
Application received  5/4/2018 DONE
Application submitted via PDS Online on May 4 2018 11:43AM
Intake Approval  5/4/2018 PASS
Plan assigned to (Tim)5/4/2018 5/4/2018 DONE
DetailsTim Frost
Sprinkler Plan Check5/4/2018 5/4/2018 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  5/4/2018 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  5/4/2018 DONE
DetailsTim Frost
Permit Ready to Issue  5/4/2018 DONE