Permit NumberFIR18-00587
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 1671 N MOCKBEE PL
Project Namel4 sherman
Customer Number 
ePlanReviewYes
Description
[I4 Sherman - 1671 Mockbee]
The fire sprinkler scope of work consists of a new single family two level home. The system is designed as a passive purge system. The system utilizes CPVC piping and residential type sprinklers.

[BLD18-01614]
FIRE SPRINKLERS ARE REQUIRED. W.U.I. Zone "A". Class A roof required.
Permit for the construction of a new 2,306 sq. ft., two story (first story 1,564sq. ft., second story 742 sq. ft.) single family dwelling with 4 bedrooms, 3 bathrooms, approximately 100 sq. ft. of covered patio/porch and an 858 sq. ft. attached garage per the approved plans and any notations. Prescriptive Energy Compliance. R-1B zoning and setbacks per planning. ***RDP***

Alternative Materials and Methods:
This project includes approved code alternates to the following fire protection systems and/or building life safety systems. Please review the supplemental documents attached to this building permit case for details. Fire protection “shop drawings” shall include approved code alternate design.

• There are no AMM at this time
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled  11/20/2018 DONE
as per Tim Frot final passed-doc final
INSP-Final Inspection11/13/201811/14/201811/14/2018APASS
DetailsTim Frost
Final OK

Phone #: ###-#### >> Inspection requested via web by Stan Beus
INSP-Final Inspection11/12/201811/13/201811/13/2018AFAIL
DetailsTim Frost
- Could not ring bell.
- Sign on riser room door.
- Hanger on riser.


Phone #: ###-#### >> Inspection requested via web by Stan Beus
INSP-Final Inspection11/2/201811/8/201811/8/2018PFAIL
DetailsJim Page
Add fire sprinkler head to get proper floor coverage due to added duct. Irrigation timer is not installed, need to test irrigation shutdown with flow switch activation.

Colton Cox is the contact for this final inspection. Thank you for your help. Have a nice day. Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Sprinkler Rough-in/Hydro11/8/201811/8/201811/8/2018PDONE
DetailsJim Page
Hydrostatic completed and witnessed with city pressure (system does not have FDC so static pressure for hydro is allowed), no pressure loss observed.
INSP-Sprinkler Rough-in9/27/20189/27/20189/27/2018PPASS
DetailsJim Page
Tenting inspection complete, overhead fire sprinkler piping approved for cover.

Tinting needs to be completed. Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Sprinkler Rough-in9/14/20189/17/20189/18/2018PPASS
DetailsJim Page
Phone #: ###-#### >> Inspection requested via web by Stan Beus

____________
Passed

INSP-Sprinkler Rough-in9/14/20189/17/20189/14/2018ACANC
DetailsJim Page
Phone #: ###-#### >> Inspection requested via web by Stan Beus Inspection cancelled from web by: Stan Beus
Plan resubmittals received  7/27/2018 DONE
Sprinkler Plan Check7/27/2018 7/27/2018 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  7/27/2018 DONE
DetailsTim Frost
Permit Ready to Issue  7/27/2018 DONE
Issue and Print Permit  7/27/2018 DONE
Intake Approval  7/26/2018 PASS
Plan assigned to (Tim)7/26/2018 7/26/2018 DONE
DetailsTim Frost
Sprinkler Plan Check7/26/2018 7/26/2018 FAIL
DetailsTim Frost
1st review completed  7/26/2018 PASS
DetailsTim Frost
Miscellaneous action  7/26/2018 DONE
DetailsTim Frost
Emailed contractor in regards to failed review.
Application received  7/24/2018 DONE
Application submitted via PDS Online on Jul 24 2018 6:13PM