Permit Information
Permit NumberFIR18-00601
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 2045 S HUDSON AVE
Project NameSkyline Apartments Bldg H
Customer NumberUDG ONLY
ePlanReviewYes
Description
[Skyline Apartments Building H - UDG Only] - Quick Permit
Install a new 2" CPVC line into the new Apartment Bldg. This is only for the underground line. A full fire sprinkler submittal will follow at a later date.

[BLD17-04629]
Building H: (SKYLINE APARTMENTS- BUILDING TYPE 4, Building H)(12 units) The NFPA 13-R fire sprinkler system is used for occupancy and for story increase. To construct a 17,898 square foot three story VB Type of Construction apartment building (5,984 sq. ft. 1st story 5,957 sq. ft. 2nd story 5,597 sq. ft. 3rd story. Work is to include concrete footings, concrete foundations, concrete slabs on grade, wood stud bearing walls, wood stud shear walls, fiberglass shingles, 1-hr dwelling unit separations, 1 hour fire barriers for stair and breezeways, rated doors in breezeway, interior nonbearing walls, millwork, and finishes. Special Inspection is NOT required. The roof truss design is a deferred submittal item. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13-R as regulated by the Fire Department. Separate fire sprinkler permits shall be obtained prior to beginning any modification or installation work on such systems. **ajs**192 unit apartment project with (9) apartment buildings, clubhouse, and associated site work
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection8/27/20198/28/20198/28/2019PPASS
DetailsJim Page
Final underground supply inspection complete.

Jon Beazer is the contact. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Supply line flush8/26/20198/27/20198/27/2019ADONE
DetailsJim Page
Underground main line flush after pipe break complete.

Jon Beazer is the contact. Stacey with Suez has been contacted and is planning on this flush being around 9:30 AM. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Final Inspection8/27/20198/27/20198/27/2019PCANC
DetailsJim Page
Jon Beazer is the contact. The final was done this morning, this is just the paper trail. Call Jon Beazer to answer any questions. Thank you for your hard work! Phone #: ###-#### >> Inspection requested via web by Stan Beus Inspection cancelled from web by: Stan Beus
INSP-Sprinkler Rough-in/Hydro4/11/20194/12/20194/12/2019ADONE
DetailsJim Page
Hydrostatic test for underground supply witnessed, no pressure loss observed.

Gerardo Arce is the contact. He wants this to be a hydro only inspection. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Supply line flush4/9/20194/11/20194/11/2019ADONE
DetailsJim Page
Underground main line flush complete.



Gerardo Arce is the contact. Stacy from Suez has this on his schedule, contact him for a more specific time. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Supply line flush11/8/201811/13/201811/13/2018PCANC
DetailsTroy Cobbley
Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Sprinkler Rough-in/Hydro11/8/201811/13/201811/13/2018PCANC
DetailsTroy Cobbley
Problem with hydro pump

Phone #: ###-#### Inspection requested via web by Stan Beus
INSP-Sprinkler Rough-in8/1/20188/2/20188/2/2018ACANC
DetailsJim Page
Inspection request cancelled per conversation with point of contact, inspection will be rescheduled for a later date.

Underground rough to cover Phone #: ###-#### Inspection requested via web by Stan Beus
Sprinkler Plan Check8/1/2018 8/1/2018 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  8/1/2018 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  8/1/2018 DONE
DetailsTim Frost
Permit Ready to Issue  8/1/2018 DONE
Issue and Print Permit  8/1/2018 DONE
Application received  7/31/2018 DONE
Application submitted via PDS Online on Jul 31 2018 7:33AM