Permit Information
Permit NumberFIR18-00696
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 9196 W EMERALD ST Unit: 110
Project NameVANILLA #110 TI
Customer Number 
ePlanReviewYes
Description
[Vanilla TI - Suit 110] - Quick Permit
Add, plug and relocate sprinklers to accommodate new wall and ceiling configuration.

[BLD18-02517]
NO OCCUPANCY ALLOWED UNDER THIS PERMIT. TENANT SHALL APPLY FOR CERTIFICATE OF OCCUPANCY PRIOR TO OCCUPYING THE SPACE. Permit is to remodel an existing 3,815 sq. ft. tenant space by dividing it into two separate tenant spaces, this vacant tenant space is to be 1,566 sq. ft. and the remaining vacant tenant space is to be 2,249 sq. ft. created under BLD18-02488. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frames, removal of select millwork, construction of select interior nonbearing wall to demise tenant spaces, construction of new walls to create (2) new accessible restrooms, select new door/door frames, new Hi/Lo drinking fountain, new plumbing fixtures, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection10/11/201810/11/201810/11/2018PPASS
DetailsJim Page
Final fire sprinkler system inspection complete.

We would like to perform this in conjunction with the fire life safety for the BLD. Please call Terry with questions. Phone #: ###-#### Inspection requested via web by Jeff Packham
Plan resubmittals received  9/12/2018 DONE
DetailsTim Frost
Plan assigned to (Tim)9/12/2018 9/12/2018 DONE
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  9/12/2018 DONE
DetailsTim Frost
Permit Ready to Issue  9/12/2018 DONE
plan mod approved
CHANGE STATUS TO (ISS)  9/12/2018 DONE
(F) Reprint permit  9/12/2018 DONE
INSP-Sprinkler Rough-in9/10/20189/11/20189/11/2018APASS
DetailsTroy Cobbley
Terry-to cover Phone #: ###-####

Ok to Cover
Intake Approval  9/6/2018 PASS
DetailsTim Frost
Plan assigned to (Tim)9/6/2018 9/6/2018 DONE
DetailsTim Frost
Sprinkler Plan Check9/6/2018 9/6/2018 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  9/6/2018 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  9/6/2018 DONE
DetailsTim Frost
Permit Ready to Issue  9/6/2018  
Issue and Print Permit  9/6/2018 DONE
Application received  9/5/2018 DONE
Application submitted via PDS Online on Sep 5 2018 3:33PM