Permit Information
Permit NumberFIR18-00761
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 720 E PARK BLVD Unit: 100
Project NameST. LUKE'S REAL ESTATE TI
Customer Number 
ePlanReviewYes
Description
[St. Lukes WGCP - Real Estate Office} - Quick Permit
INSTALL NEW QUICK RESPONSE SPRINKLER HEADS TO THE NEW WALL AND CEILING LAYOUT.

[BLD18-02665]
The fire sprinkler system is used for unlimited area of the building. Permit is to remodel an existing 3,246 sq. ft. business space on the 1st floor within the existing building. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select operable panels, removal of select door/door frames, removal of select millwork, removal of select suspended acoustic and gypsum ceiling, removal of select ceiling soffit, construction of select interior nonbearing walls to make (3) offices, (2) consult rooms, a reception area, a conference room, open office area, open break/work area, an access control open office area, a security office and an IT room, select wall infill, select new door/door frames, new suspended acoustic ceiling, new light fixtures, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection11/7/201811/9/201811/9/2018APASS
DetailsJim Page
Final fire sprinkler inspection for area of work complete.

randy courtwright Phone #: ###-#### Inspection requested via web by Brodie Stenquist
INSP-Final Inspection11/6/201811/7/201811/7/2018ACANC
DetailsTroy Cobbley
Rescheduled for friday per Randy

r=Randy Courtwright Phone #: ###-#### Inspection requested via web by Brodie Stenquist
INSP-Sprinkler Rough-in10/11/201810/12/201810/12/2018APASS
DetailsJim Page
Rough to cover inspection for overhead fire sprinkler piping in area of work complete, approved for cover.

randy courtwright Phone #: ###-#### Inspection requested via web by Brodie Stenquist
Issue and Print Permit  10/8/2018 DONE
Intake Approval  10/5/2018 PASS
DetailsTim Frost
Plan assigned to (Tim)10/5/2018 10/5/2018 DONE
DetailsTim Frost
Sprinkler Plan Check10/5/2018 10/5/2018 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  10/5/2018 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  10/5/2018 DONE
DetailsTim Frost
Permit Ready to Issue  10/5/2018 DONE
MET
Application received  10/3/2018 DONE
Application submitted via PDS Online on Oct 3 2018 3:26PM