Permit Information
Permit NumberFIR18-00770
StatusFinaled
Name ABSOLUTE FIRE PROTECTION
Site Address 611 S 8TH ST Unit: 103
Project NameKiwi Shake & Bake TI @ Afton1
Customer Number 
ePlanReviewYes
Description
[Kiwi Shake & Bake TI] - Quick Permit
Ste 103. Add 6 SSP for new Kitchen & Bathrooms and 2 HSW for OH Doors

[BLD18-01628]
The fire sprinkler system (NFPA 13 below and above the podium per the “Special Design Standards for Type V Construction” ordinance) is used for story and height increase. To remodel a 1,992 square foot, one story shell space located on the ground story to be used as a bar/restaurant. Work is to include an interior concrete slab on grade floor, replacing existing storefront glazing in 2 locations with 2 new vertical sliding sectional doors, a mechanical and storage mezzanine, two toilet rooms accessible to the disabled, interior decorative awnings, kitchen equipment, a bar, back bar equipment, millwork, and finishes. One new sectional door extends to the floor and the other new sectional door extends to the top of a bar counter with an insulated wall below. Tube steel jambs with steel base plates will extend from the floor to the underside of existing horizontal wind girts and will be welded to the underside of the existing wind girts and be insulated or have a thermal break. The steel jambs and wind girts will be used to support tracks for the vertical sliding sectional doors and to resist out-of-plane lateral loads. Special Inspection is required for welding and for anchors post-installed in hardened concrete. Work related to the new 386 square foot mechanical and storage mezzanine includes metal joists and a gypsum board ceiling, noncombustible floor deck with wood floor finish, bearing walls, and a pull-down ships ladder for access. The mechanical and storage mezzanine is required to be constructed on noncombustible materials. A 510 square foot fenced sidewalk drinking/dining area will also be created. The fence will be 3 feet tall. There is an existing grease trap that was installed under the original permit anticipating a restaurant in this space. A ventless enclosed electric fryer will be installed. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection12/7/201812/7/201812/7/2018PPASS
DetailsJim Page
Final fire sprinkler inspection for area of work complete.

Phone #: ###-#### Inspection requested via web by Sam Ball
INSP-Sprinkler Rough-in10/17/201810/18/201810/18/2018APASS
DetailsJim Page
Rough to cover inspection for area of work complete, sidewall heads shown on plan top cover under roll up doors have been deleted, heads are not required, door does not roll back more than 48 inches.

Plans are on the counter behind the bar. Phone #: ###-#### Inspection requested via web by Sam Ball
Intake Approval  10/8/2018 PASS
DetailsTim Frost
Plan assigned to (Tim)10/8/2018 10/8/2018 DONE
DetailsTim Frost
Sprinkler Plan Check10/8/2018 10/8/2018 PASS
DetailsTim Frost
Please, see attached comments.
1st review completed  10/8/2018 PASS
DetailsTim Frost
PLANS/APPL TAKEN TO FRONT DESK  10/8/2018 DONE
DetailsTim Frost
Permit Ready to Issue  10/8/2018 DONE
met
Issue and Print Permit  10/8/2018 DONE
Application received  10/5/2018 DONE
Application submitted via PDS Online on Oct 5 2018 7:02PM