Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberFIR19-00127
StatusFinaled
Name PROTEX
Site Address 3101 N SYCAMORE DR
Project NameBoise Fire Station #9
Customer Number 
ePlanReviewYes
Description
Install new code compliant fire alarm system. This work is associated with building permit BLD18-02497.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection10/16/201910/17/201910/17/2019APASS
DetailsTroy Cobbley
Permit finaled.

Contact is Morgan. Phone #: ###-#### Inspection requested via web by Morgan Ahten
INSP-Final Inspection10/16/201910/16/201910/16/2019PCANC
DetailsTroy Cobbley
To be rescheduled due to time constraints due to work load. Contact is Dirk. Phone #: ###-#### Inspection requested via web by Morgan Ahten
INSP-Final Inspection10/14/201910/15/201910/15/2019PFAIL
DetailsJim Page
Fire sprinkler, fire alarm and fire alarm communicator trades need to be coordinated together to complete this inspection. Provide a record of testing from the monitoring service as discussed. Smoke detector in dayroom is over 23 feet from corner, relocate for code compliance. Provide fan shutdown on large ceiling fan on appuratus floor. Fire alarm system is an engineered system, a resubmittal for plan mod is required to show the addition of the smoke detector in the captians quarters and the addition of the fan shutdown relay. No devices were tested and monitoring was not verified.


Contact is Dirk. Phone #: ###-#### Inspection requested via web by Morgan Ahten
Plan Modification Accepted  10/15/2019 DONE
as built per morgan with protex
Plan assigned to (Lee)10/15/2019 10/15/2019 DONE
DetailsLee G Meredith
Intake Approval  10/15/2019 PASS
1st review completed  10/15/2019 PASS
Alarm Plan Check10/15/2019 10/15/2019 PASS
DetailsLee G Meredith
PLANS TAKEN FRONT DESK ALARM  10/15/2019 DONE
As built - No fee.
Permit Ready to Issue  10/15/2019 DONE
CHANGE STATUS TO (ISS)  10/15/2019 DONE
AS BUILT
Plan resubmittals received  4/17/2019 DONE
Alarm Plan Check4/16/2019 4/17/2019 PASS
DetailsLee G Meredith
PLANS TAKEN FRONT DESK ALARM  4/17/2019 DONE
Passed with comments and drawing notes.
Permit Ready to Issue  4/17/2019 DONE
met
Issue and Print Permit  4/17/2019 DONE
Plan assigned to (Lee)2/20/2019 2/20/2019 DONE
DetailsLee G Meredith
1st review completed  2/20/2019 FAIL
See 1st review comments.
Application received  2/19/2019 DONE
Application submitted via PDS Online on Feb 19 2019 2:45PM