INSP-Final Inspection | 10/21/2019 | 10/22/2019 | 10/22/2019 | A | PASS |
Troy Cobbley
|
|
|
Permit finaled
Contact Ken Orahood ###-#### 30 Min prior to Final Insp start please
Thank YOU Phone #: ###-#### Inspection requested via web by Teri Cruickshank
|
INSP-Sprinkler Rough-in | 9/13/2019 | 9/13/2019 | 9/13/2019 | P | PASS |
Jim Page
|
|
|
Rough to cover inspection for overhead fire sprinkler piping in area of work complete, approved for cover.
Contact Noemi Carrero - ###-#### 30min prior to RTC Insp start please.
Thank YOU Phone #: ###-#### Inspection requested via web by Teri Cruickshank
|
INSP-Sprinkler Rough-in | 8/1/2019 | 8/2/2019 | 8/2/2019 | P | PASS |
Troy Cobbley
|
|
|
Rough-in passed. Will need another rough to cover inspection once the flex heads have been placed.
Contact Tanner Loomis ###-#### 30 Min prior to RTC Insp strart please
Thank YOU Phone #: ###-#### Inspection requested via web by Teri Cruickshank
|
INSP-Sprinkler Rough-in | 8/1/2019 | 8/1/2019 | 8/1/2019 | P | NR |
Troy Cobbley
|
|
|
The contractor scheduled the wrong permit/job. I still spoke to the fitter and general contractor about the sprinkler modifications. An inspection for this project will be scheduled for tomorrow.
Contact Tyler Loomis ###-#### 30 min prior to RTC insp start please.
Thank YOU Phone #: ###-#### Inspection requested via web by Teri Cruickshank
|
INSP-Sprinkler Rough-in | 7/29/2019 | 7/30/2019 | 7/30/2019 | P | FAIL |
Troy Cobbley
|
|
|
Provide plan modifications/hydraulic calculations showing the actual piping layout now that two pendant heads are being piped from a single 1" outlet. Contact Tanner Loomis ###-#### 30 min prior to RTC Insp start please.
Thank YOU Phone #: ###-#### Inspection requested via web by Teri Cruickshank
|
INSP-Sprinkler Rough-in | 7/25/2019 | 7/26/2019 | 7/26/2019 | A | PASS |
Troy Cobbley
|
|
|
See the city approved plans for the four locations where piping can be covered above the hard lids.
Contact Tanner Loomis - ###-#### 30 min prior to RTC Insp Start please, RTC is for Hard Lid heads only.
Thank YOU Phone #: ###-#### Inspection requested via web by Teri Cruickshank
|
Intake Approval | | | 6/10/2019 | | PASS |
Mark Stumbaugh
|
|
|
|
Plan assigned to (Stumbaugh) | 6/10/2019 | | 6/10/2019 | | DONE |
Mark Stumbaugh
|
|
|
|
Sprinkler Plan Check | 6/10/2019 | | 6/10/2019 | | PASS |
Mark Stumbaugh
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/10/2019 | | DONE |
Mark Stumbaugh
|
|
|
|
Permit Ready to Issue | | | 6/10/2019 | | DONE |
|
|
|
met
|
Issue and Print Permit | | | 6/10/2019 | | DONE |
|
|
|
|
Intake Approval | | | 6/7/2019 | | FAIL |
Mark Stumbaugh
|
|
|
|
Application received | | | 5/22/2019 | | DONE |
|
|
|
Application submitted via PDS Online on May 22 2019 10:47AM
|
Intake Approval | | | 5/22/2019 | | FAIL |
Mark Stumbaugh
|
|
|
Awaiting BLD Permit to be issued
|