Description
(Anser Charter School -Building One) - To remodel an existing 36,411 square foot charter school building per the approved plans. Work to include: selective minor interior demolition; new construction of interior non-bearing wall partitions to create three additional classrooms; infill existing wall openings per plans; provide new doors and associated hardware; installation of a suspended acoustical panel ceiling system; concrete floor slab work; install new 2X6 header to span full width of hallway; upgrade the lighting layout; modify the existing exit lighting; related interior finishes in compliance with chapter 8 of the 2006 IBC; electrical, mechanical work; and all other work per the approved plans, attached plan review report, engineering, and other reviewing agencies approvals. NOTE: This building is currently partially fire sprinklered. The fire sprinkler system will be extended into the un-sprinklered portions of the building per NFPA #13 as regulated by the fire department and will require a separate permit. The Fire alarm system has already been extended into all areas of the building under a previous remodel. An existing Fire wall separates building one from building two. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
GCB-Final9/1/20109/2/20109/2/2010APASS
DetailsDave Hannah
Scope: FinalContact: Rick @ ###-####Call 30 mins in advance please
GCB-Ceiling Grid8/17/20108/18/20108/18/2010APART
DetailsDave Hannah
Scope: Ceiling GridContact: Rick @ ###-####Please call 30 mins in advance ok to cover ceiling in hallway
GCB-Energy8/3/20108/4/20108/4/2010APASS
DetailsDave Hannah
Scope: Energy (This is for insulation related to the ceiling)Contact: Brent @ ###-####Call in advance roof insulation blowen in to fill spaces to under 6 inches and batted on rest of areas with no insulation
GCB-Energy7/9/20107/12/20107/12/2010ACANC
DetailsDave Hannah
Scope: Applicant has requested a "cover" inspection. Energy seems like the next logical inspection, but please let me know if I need to change this task.Contact: Rick @ ###-####**Call 30 mins in advance**
GCB-Framing7/12/20107/12/20107/12/2010APASS
DetailsDave Hannah
ok to cover ceiling struc bracing for mec units ok
GCB-Framing6/29/20106/30/20106/30/2010APASS
DetailsMike Jordan
Scope of Inspection: FramingContact: Rick @ 8665058**Call 30 minutes in advance**. Interior steel stud framed walls for new classrooms.
Plan assigned to (SRZ)5/26/20105/26/20106/16/2010 DONE
DetailsSam Zahorka
Routing - PLAN CHECK6/2/2010 6/16/2010 PASS
DetailsSam Zahorka
PLANS/APPL TAKEN TO FRONT DESK  6/16/2010 DONE
DetailsSam Zahorka
Issue and Courier  6/16/2010 DONE
Plan resubmittals received  6/3/2010 DONE
Routing - PLAN CHECK5/26/2010 6/2/2010 FAIL
DetailsSam Zahorka
Plans are incomplete.
1st review completed  6/2/2010 DONE
DetailsSam Zahorka
Plan resubmittals requested  6/2/2010 DONE
DetailsSam Zahorka
Spoke with Brent at LCA architects
Application received  5/18/2010 DONE