Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberGCB12-00089
StatusFinaled
Name RS Wilson Investments LTD, CO
Site Address 500 E 42ND Unit: J
Project NameBLD2012-00089
Customer Number 
ePlanReviewNo
Description
To repair an existing header over a 10'-6" opening in an existing 12' wide x 56' long manufactured home and repair an existing header over a 10'-6" opening in the existing 12' wide x 20' long attached addition. Work to include: Modify the existing 2 x 4 header at the addition side as indicated in the engineering sketches and calculations; install a new header over the opening on the manufactured home side per the engineered drawings; provide new connections, columns for bearing, and all other work per the approved engineered drawings, attached plan review report, the structural inspectors final approval, and other reviewing agencies comments. The Building Official has determined carbon monoxide poisoning, smoke and fire related hazards to be specific hazards associated with buildings and/or structures without smoke and carbon monoxide detection and alarm systems that do not meet current building codes. Carbon monoxide poisoning, smoke and fire related hazards are substantial hazards because the likelihood of death and or injury from said hazards increases in buildings and/or structures. The existing portions of buildings or structures with non-existent or inadequate smoke and carbon monoxide detection and alarm systems that do not meet current building codes must be retrofitted to meet current code requirements. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
GCB-Final8/7/20128/7/20128/7/2012APASS
DetailsDave Hannah
Scott @ ###-####
PM inspection requested
GCB-Final8/3/20128/6/20128/7/2012PNH
DetailsDave Hannah
Scott @ ###-####
PM inspection requested
GCB-Framing7/27/20127/30/20127/30/2012PPASS
DetailsMike Jordan
Scott @ ###-####
PM Inspection - Call in advance
GCB-Courtesy7/23/20127/23/20127/23/2012PDONE
DetailsDave Hannah
Scott @ ###-####
PM Inspection - Call in advance
Issue and Courier  7/20/2012 DONE
DetailsBarbara Stitt
Plan assigned to (SRZ)7/13/20127/13/20127/19/2012 DONE
DetailsSam Zahorka
Routing - PLAN CHECK7/13/2012 7/19/2012 PASS
DetailsSam Zahorka
1st review completed  7/19/2012 DONE
DetailsSam Zahorka
PLANS/APPL TAKEN TO FRONT DESK  7/19/2012 DONE
DetailsSam Zahorka
Application received  7/5/2012 DONE