Permit Information
Permit NumberGCB12-00143
StatusFinaled
Name TOM COLLINS
Site Address 108 W 37TH ST
Project NameBLD2012-00143
Customer Number 
ePlanReviewNo
Description
EPSCO - **7/24/13 PLAN MODIFICATION TO ADD THE OVEN EQIPMENT TO THIS PERMIT. SEPARATE MECHANICAL AND ELECTRICAL PERMITS ARE REQUIRED AND PASSED PRIOR TO THIS PERMITS FINAL AND OCCUPANCY. SRZ** To construct a new 50' X 100', 5,000 square foot, One story, VB-non rated, commercial shop building and related site improvements for a powder coating business. The building will be constructed of CMU exterior walls with painted CMU banding, a concrete slab floor, open web joist roof structure with mechanically fastened single-ply roofing. All work per the approved plans, attached plan review comments, and conditions of all reviewing agencies for this project. Racking exceeding 8' in height is NOT approved under this permit. A Certificate of Occupancy with the occupant load total is to be issued when completed and approved. This building is NOT fire sprinklered. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
GCB-Final7/25/20137/25/20137/25/2013PPASS
DetailsJim Sly
Odie ###-####
Telephone call  7/24/2013 DONE
DetailsSam Zahorka
spoke with Joel Bradshaw with Boise FIre and let him know about the addition of the oven to this permit. Let him know separate trade permits are required to be pulled and approved for the connection and hook up of the oven prior to final of this permit. He said he is ok with this.
Meeting  7/24/2013 DONE
DetailsSam Zahorka
meeting with the mechanical reviewer, mechanical inspector, and the building official. I was directed to add the oven equipment to scope of this permit and required separate trade permits be pulled and finaled prior to final and occupancy of this permit.
Telephone call  7/19/2013 DONE
DetailsSam Zahorka
Recieved a telephone call from Lori at Garden City. A mechanical oven has been added to the scope of this project with no approvals. A plan modification is required to include the oven. I called the architect and left a message. Waiting for the architect to call me back. SRZ
GCB-Final6/21/20136/21/20136/21/2013PNR
DetailsTony Young
Tim ###-####,, NEED TRADES PER CONTRACTOR
GCB-Framing4/16/20134/17/20134/17/2013APASS
DetailsMike Jordan
Tim Sparks ###-#### please call 1/2 hour advance. Interior steel stud framed walls for restroom.
GCB-Energy3/26/20133/26/20133/26/2013PPART
DetailsTom Arcoraci
Tim ###-#### please give half hour notice if possible
GCB-Framing3/21/20133/21/20133/21/2013PPASS
DetailsMike Jordan
Tim ###-#### please call half hour before arrival. Roof framing and diaphragm ok as well as all trusses.
GCB-Masonry3/7/20133/8/20133/8/2013PPASS
DetailsJim Sly
Tim Sparks ###-#### please call in advance; grout pour at 2pm
CMU grout pour !2 to 16' OK pending MTI special insp, tests and approvals.
GCB-Masonry3/5/20133/6/20133/6/2013APART
DetailsMike Jordan
Ken ###-#### also has MTI special inspection scheduled. 12ft. to 16ft. elevation on masonry walls. Grout being placed when arived on site. MTI on site also. ok.
GCB-Masonry3/4/20133/4/20133/4/2013PPART
DetailsJim Sly
Tim @ ###-####
Special Inspection scheduled with MTI
Pouring grout at 1:30 p.m.
Please call in advance
CMU wall lift 4 to 8ft.....OK pending MTI insp. tests and approvals.
GCB-Masonry3/1/20133/1/20133/1/2013PPART
DetailsJim Sly
Tim @ ###-####
Call in advance
Special Inspection also scheduled
CMU wall up to 4' lift.......OK pending MTI insp, tests and approvals.
GCB-Masonry2/27/20132/28/20132/28/2013APART
DetailsTony Young
Tim @ ###-####
Late morning inspection - call in advance,, 1st lift,, work in progress,, ok pending special inspection
GCB-Fndatn/slab ins/fld vent2/19/20132/20/20132/20/2013APASS
DetailsJim Sly
Tim Sparks ###-####
OK pend MTI insp, tests and approvals..
GCB-Footing2/15/20132/15/20132/19/2013ADONE
DetailsDave Hannah
TIM SPARKS ###-####
GCB-Footing2/15/20132/15/20132/15/2013PPASS
DetailsJim Sly
Tim Sparks Phone #: ###-#### please call prior to insepction
Footing OK pending MTI special inspection, tests and approvals.
Plan assigned to (SRZ)12/11/201212/11/20121/14/2013 DONE
DetailsSam Zahorka
1st review completed. Waiting for Mechanical design for the spray booth.
CHANGE STATUS TO (ISS)  1/14/2013 DONE
DetailsSam Zahorka
Routing - Mechanical Review12/19/2012 12/19/2012 PASS
DetailsTroy James
Telephone call  12/11/2012 DONE
DetailsSam Zahorka
Spoke with and received an email from Gordan with NACFR. Explained the addition of a spray booth to this permits scope of work requires an engineered mechanical design for mechanical plan review approvals prior to issuance. I offered to call the architect and request the additional mechanical information.
Telephone call  12/11/2012 DONE
DetailsSam Zahorka
Called the architect Tom Collins with Steed Construction and requested a fully engineered, stamped and signed, mechanical design for the addition of the spray booth. Let him know the exhaust for powder coating is regulated by the 2009 INC and IFC. He stated he would get the mechanical design and submitt to Garden City.
Telephone call  12/10/2012 DONE
DetailsSam Zahorka
I spoke with Romeo and Gordon with the Fire department. Waiting for answers to Fire reviews questions. Additional building/mechanical reviews might be required based on the design professionals answers to fire review. Mechanical exhaust and Fire extinguishers and non-combustible wall construction for powder coating processes could be required. I called Garden City and let them know. Waiting for responses.
Routing - PLAN CHECK12/10/2012 12/10/2012 PEND
DetailsSam Zahorka
Spoke with mechanical review. Waiting for answers from the design professional based on fire plan reviews questions. Mechanical design submittals stamped and signed plans possibly required for the design of a powder coating room or spray booths with a mechanical plan review required prior to issuance.
CHANGE STATUS TO (REV)  12/10/2012 DONE
DetailsSam Zahorka
Due to Mechanical and Fire code issues. Pending answers from the architect.
Telephone call  12/5/2012 DONE
DetailsSam Zahorka
Spoke with Leon w/ Garden City, Tom Collins the Architect, and Gordon with the Fire department about the confusion about the Fire sprinkler protection for this building. The architect meant to not provide fire sprinklers. There is no building code reason to require fire sprinklers. I requested Leon to re-route back to fire plan review to verify the removal of fire sprinklers would be ok per the Fire code. Issuance is pending Fire review approval
Plan assigned to (SRZ)10/30/201210/30/201211/30/2012 DONE
DetailsSam Zahorka
Routing - PLAN CHECK10/30/2012 11/30/2012 PASS
DetailsSam Zahorka
1st review completed  11/30/2012 DONE
DetailsSam Zahorka
PLANS/APPL TAKEN TO FRONT DESK  11/30/2012 DONE
DetailsSam Zahorka
Issue and Courier  11/30/2012 DONE
DetailsBarbara Stitt
Plan resubmittals received  11/14/2012  
Received 3 copies of sheet C-1, ESC sheet, 3 copies of Storm narrative, 3 copies of Drainage Pond Design & Pond Drainage Calcs, 3 Copies of O & M, 3 copies of Geotechnical Report and taken to Sam Zahorka's desk
Application received  10/26/2012 DONE
GCB-Final7/25/20137/25/2013 P 
DetailsMike Jordan
Odie ###-####