Permit Information
Permit NumberGCB14-00006
StatusFinaled
Name SCHNEIDER CUSTOM HOMES INC
Site Address 3796 N WILLOWBAR LN
Project NameBLD2014-00006
Customer Number 
ePlanReviewNo
Description
To construct an interior remodel of an existing 2,482 square foot (1493 sq.ft. 1st story / 989 sq.ft. 2nd story) Single family dwelling which will increase the 2nd floor by an additional 108 square feet for a new walk-in closet. Work to include: demo select interior walls on the 1st story and 2nd story and provide new bearing per plans; relocate the master bedroom, bathroom, and walk-in closet to the 2nd story; and resize the existing bedroom on the 2nd story. All work per the approved plans, plan review report, and all other reviewing agencies approvals. The Building Official has determined carbon monoxide poisoning, smoke and fire related hazards to be specific hazards associated with buildings and/or structures without smoke and carbon monoxide detection and alarm systems that do not meet current building codes. Carbon monoxide poisoning, smoke and fire related hazards are substantial hazards because the likelihood of death and or injury from said hazards increases in buildings and/or structures. The existing portions of buildings or structures with non-existent or inadequate smoke and carbon monoxide detection and alarm systems that do not meet current building codes must be retrofitted to meet current code requirements. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
GCB-Final8/18/20148/19/20148/19/2014APASS
DetailsMike Jordan
Dylan ###-#### call to meet onsite. Structural final only ok.
GCB-Framing1/30/20141/31/20141/31/2014PPASS
DetailsJim Sly
Dillon ###-####
Plan assigned to (SRZ)1/17/20141/17/20141/29/2014 DONE
DetailsSam Zahorka
1st review completed
Routing - PLAN CHECK1/29/2014 1/29/2014 PASS
DetailsSam Zahorka
PLANS/APPL TAKEN TO FRONT DESK  1/29/2014 DONE
DetailsSam Zahorka
Issue and Courier  1/29/2014 DONE
DetailsBarbara Stitt
Telephone call  1/27/2014 DONE
DetailsSam Zahorka
Called the applicant. requested additional structural information. He scheduled a meeting for Wednesday moring at Garden City to go over needed corrections.
Routing - PLAN CHECK1/24/2014 1/24/2014 FAIL
DetailsSam Zahorka
Sam Zahorka
Routing - Mechanical Review1/17/2014 1/24/2014 PASS
DetailsTroy James
no mechanical to review
1st review completed  1/24/2014 DONE
DetailsSam Zahorka
Application received  1/17/2014 DONE