Permit Information
Permit NumberGCB15-00036
StatusFinaled
Name The Rag Company
Site Address 9165 W CHINDEN BLVD
Project NameBLD2015-00036
Customer Number 
ePlanReviewNo
Description
Suites 102 and 103 - To install steel storage racking exceeding 8' in height per approved plans and structural engineering. SPECIAL INSPECTIONS ARE REQUIRED. Work to include: Each unit will be bolted to the floor and have more than 36" isles between rows. The design, testing and utilization of industrial steel storage racks shall be in accordance with the RMI/ANSI MH 16.1. A Letter of Completion is to be issued when done. EACH RACKING SYSTEM SHALL HAVE A PLAQUE LOCATED AT EACH RACKING SYSTEM STATING THE MAXIMUM WEIGHT TO BE STORED ON THAT PERTICULAR RACKING SYSTEM PER THE ENGINEERS CRITERIA STATED ON THE PLANS FOR EACH RACKING SYSTEM. This building is Fire Sprinklered and has an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Fire Department. Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. Final approval will be subject to satisfactory field inspection. **SRZ**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
GCB-Final6/29/20156/29/20156/29/2015PPASS
DetailsJim Sly
Carolyn ###-####
MTI special inspection of bolting for racking approved......File # B15066C
GCB-Final6/23/20156/23/20156/23/2015PNR
DetailsJim Sly
Caroline ###-#### - requested call ahead
Not Ready.........Called Caroline and asked her if she had the paperwork on site from the Special inspection agency for bolting of rack system. She said no. Will call when paperwork, showing approval is on site.
GCB-Final6/18/20156/19/20156/19/2015APART
DetailsMike Jordan
Caroline ###-####. Needs special inspection on insatlled anchors. Everything else ok.
FIRE-Final Inspection6/17/20156/18/20156/18/2015PPASS
DetailsKatie Marron
Fire Life Safety pass.
GCB-Final6/16/20156/16/20156/17/2015PNR
DetailsJim Sly
Caroline ###-#### - storage racks
Not ready.....Need fire final approval.
Plan assigned to (SRZ) 3/30/20155/1/2015 DONE
DetailsSam Zahorka
1st IBC review
PLANS/APPL TAKEN TO FRONT DESK  5/1/2015 DONE
DetailsSam Zahorka
Issue and Courier  5/1/2015 DONE
Routing - PLAN CHECK4/10/2015 4/20/2015 PASS
DetailsSam Zahorka
1st review completed  4/20/2015 DONE
DetailsSam Zahorka
Routing - FIRE3/31/20153/30/20154/10/2015 PASS
DetailsScott Arellano
Approved with gneral storage conditions. Cumulative storage is less than 500 sq.ft; therefore the provisions of IFC chapter 32 are not applicable. The building plan or application does not indicate if this is a fire sprinklered building. Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings, as applicable.
Routing - Public Works3/30/20153/30/20153/31/2015 PASS
DetailsBeverly Mountain
Application received  3/27/2015 DONE
via Garden City Web Service