GCE-Final | 2/21/2014 | 2/24/2014 | 2/24/2014 | P | PASS |
Rock A. Hudson
|
|
|
Jim ###-#### final ok
|
GCE-Final | 2/12/2014 | 2/14/2014 | 2/14/2014 | A | FAIL |
Rock A. Hudson
|
|
|
Jim ###-####, Call first BCC Energy- At least 50% lamps shall be energy efficient.
|
GCE-Permanent Service | 12/4/2013 | 12/4/2013 | 12/4/2013 | P | PASS |
Rock A. Hudson
|
|
|
###-#### 2 meters required p/s u/g n ok
|
GCE-Rough-In Permanent Service | 11/15/2013 | 11/18/2013 | 11/18/2013 | P | CANC |
Daryl DeGrange
|
|
|
Jim ###-####
|
GCE-Rough-In | 11/18/2013 | 11/18/2013 | 11/18/2013 | P | PASS |
Daryl DeGrange
|
|
|
Jim ###-#### rough-in ok cover
|
GCE-Rough-In Permanent Service | 11/14/2013 | 11/15/2013 | 11/15/2013 | P | FAIL |
Bob Reichert
|
|
|
Paula ###-#### called, corrections not made, address not posted, mc not stapled, attic access not fixed, nail plates shall be installed
|
GCE-Rough-In | 11/13/2013 | 11/14/2013 | 11/14/2013 | A | FAIL |
Daryl DeGrange
|
|
|
Jim ###-#### NEC 334.30 NM cable requires securing within 8 in. of receptacle box and 12 in. of service panel. secure SER cable. NEC 110.9 Available Fault current from tranformer
|
Application received | | | 11/13/2013 | | DONE |
|
|
|
|