Third Notice MEC | 5/6/2004 | 5/6/2004 | 6/23/2005 | | DONE |
|
|
|
Second Notice has not been responded to.
|
First Notice Sent | | 4/2/2004 | 4/21/2004 | | DONE |
|
|
|
|
DOC - Permit Finaled | 4/2/2004 | 4/2/2004 | 4/2/2004 | P | PASS |
Alan Hauser
|
|
|
Finaled by inspector at 4/2/2004 2:24:09 PM
|
Final | 4/1/2004 | 4/2/2004 | 4/2/2004 | A | FAIL |
Troy James
|
|
|
Phone #: ###-#### Internet Inspection Request from: RaChelle Meister
Provide the required combustion air at boilers within 12" of floor. Provide calcs showing how much air is being exhausted by the dryers to factor in the required duct size for make-up air. 4/2/2004 11:16:56 AM
|
Final | 4/2/2004 | 4/2/2004 | 4/2/2004 | P | PASS |
Alan Hauser
|
|
|
Phone #: ###-#### Internet Inspection Request from: RaChelle Meister
|
Final | 3/11/2004 | 3/12/2004 | 3/12/2004 | A | FAIL |
Dixie Fellows
|
|
|
Phone #: ###-#### Internet Inspection Request from: RaChelle Meister
|
Final | 2/19/2004 | 2/20/2004 | 2/20/2004 | A | PART |
Alan Hauser
|
|
|
all rooms ok, only thing left is combustion air into boiler room on roof 2/20/2004 12:15:42 PM
|
Final | 2/17/2004 | 2/18/2004 | 2/18/2004 | A | PART |
Alan Hauser
|
|
|
all rooms on 6th floor ok 2/18/2004 11:20:07 AM
|
Final | 2/12/2004 | 2/13/2004 | 2/13/2004 | A | PART |
Alan Hauser
|
|
|
all rooms ok on 5th floor 2/13/2004 12:36:44 PM
|
Final | 2/11/2004 | 2/12/2004 | 2/12/2004 | A | PART |
Alan Hauser
|
|
|
4th floor rooms ok 2/12/2004 12:39:42 PM
|
Final | 2/10/2004 | 2/11/2004 | 2/11/2004 | A | PART |
Alan Hauser
|
|
|
Phone #: ###-#### Internet Inspection Request from: RaChelle Meister
|
Final | 2/11/2004 | 2/11/2004 | 2/11/2004 | P | PART |
Alan Hauser
|
|
|
3rd floor rooms ok 2/11/2004 2:53:07 PM
|
Final | 1/29/2004 | 1/30/2004 | 1/30/2004 | A | PART |
Alan Hauser
|
|
|
2nd flr. final except hallways 1/30/2004 1:09:18 PM
|
Rough-in | 1/22/2004 | 1/22/2004 | 1/22/2004 | A | PART |
Alan Hauser
|
|
|
talked to rich about grease duct penetration through first floor ceiling into court yard shaft, ok to offset over to get 6" clearance in shaft 1/22/2004 10:33:53 AM
|
Rough-in | 1/20/2004 | 1/21/2004 | 1/21/2004 | A | PART |
Alan Hauser
|
|
|
Rich; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
|
Rough-in | 1/21/2004 | 1/21/2004 | 1/21/2004 | P | PART |
Alan Hauser
|
|
|
|
Rough-in | 1/20/2004 | 1/20/2004 | 1/20/2004 | P | FAIL |
Alan Hauser
|
|
|
no answer to my three phone calls, recall when rich is back 1/20/2004 5:19:54 PM
|
Override - Parcel Holds | 1/1/1900 | 1/1/1900 | 1/20/2004 | | |
|
|
|
|
Rough-in | 1/5/2004 | 1/6/2004 | 1/6/2004 | A | PASS |
Alan Hauser
|
|
|
final on garage area only 1/6/2004 10:44:37 AM
|
Override - Parcel Holds | | | 1/5/2004 | | |
|
|
|
|
Rough-in | 12/29/2003 | 12/30/2003 | 12/30/2003 | A | CANC |
Dixie Fellows
|
|
|
###-#### Rich TALKED TO RICH AND HE WILL RESCHEDULE WITH ALAN FOR FRI AM 12/30/2003 10:44:46 AM
|
Override - Parcel Holds | | | 12/29/2003 | | |
|
|
|
|
Rough-in | 12/17/2003 | 12/17/2003 | 12/17/2003 | P | PART |
Alan Hauser
|
|
|
unit on flrst floor elevator lobby 12/17/2003 3:11:57 PM
|
Override - Parcel Holds | | | 12/17/2003 | | |
|
|
|
|
Rough-in | 12/2/2003 | 12/3/2003 | 12/3/2003 | A | PART |
Alan Hauser
|
|
|
rich-- ###-####
|
Override - Parcel Holds | | | 12/2/2003 | | |
|
|
|
|
Rough-in | 11/13/2003 | 11/13/2003 | 11/13/2003 | A | PART |
Alan Hauser
|
|
|
dryers done on 4th floor 11/13/2003 1:42:34 PM
|
Rough-in | 11/4/2003 | 11/5/2003 | 11/5/2003 | A | PASS |
Alan Hauser
|
|
|
last units for r/i 11/5/2003 2:51:05 PM
|
Rough-in | 10/23/2003 | 10/24/2003 | 10/24/2003 | A | PART |
Alan Hauser
|
|
|
5th floor ok 10/24/2003 5:27:42 PM
|
Rough-in | 10/24/2003 | 10/24/2003 | 10/24/2003 | P | PART |
Alan Hauser
|
|
|
|
Rough-in | 10/22/2003 | 10/23/2003 | 10/23/2003 | A | CANC |
Dave Lightfoot
|
|
|
Phone #: ###-#### Internet Inspection Request from: RaChelle Meister
|
Rough-in | 10/20/2003 | 10/21/2003 | 10/21/2003 | A | PART |
Alan Hauser
|
|
|
looked at more dryer vents on 3, two left to complete 10/21/2003 1:57:58 PM
|
Rough-in | 10/14/2003 | 10/15/2003 | 10/15/2003 | A | PART |
Alan Hauser
|
|
|
looked at wall r/i on 4th floor 10/15/2003 2:28:20 PM
|
Rough-in | 10/6/2003 | 10/7/2003 | 10/7/2003 | A | PART |
Alan Hauser
|
|
|
looked at dryer vents in furred down areas on 2nd 10/7/2003 1:27:41 PM
|
Rough-in | 10/1/2003 | 10/2/2003 | 10/2/2003 | A | PART |
Alan Hauser
|
|
|
|
Rough-in | 10/1/2003 | 10/1/2003 | 10/1/2003 | P | PART |
Alan Hauser
|
|
|
all of 3rd flr. except two, wall and exhaust only 10/2/2003 4:29:35 PM
|
Rough-in | 9/23/2003 | 9/24/2003 | 9/24/2003 | A | PART |
Dave Lightfoot
|
|
|
Phone #: ###-#### Internet Inspection Request from: RaChelle Meister 3rd floor exhaust shafts ok 9/24/2003 10:45:04 AM
|
Rough-in | 9/22/2003 | 9/23/2003 | 9/23/2003 | P | CANC |
Dave Lightfoot
|
|
|
3RD FLOOR EAST. THANKS!!; Phone #: ###-#### Internet Inspection Request from: RaChelle Meister
|
Rough-in | 9/15/2003 | 9/16/2003 | 9/16/2003 | A | PART |
Alan Hauser
|
|
|
west 1st flr ok 9/16/2003 11:06:04 AM
|
Rough-in | 9/9/2003 | 9/10/2003 | 9/10/2003 | A | PART |
Alan Hauser
|
|
|
Phone #: ###-#### Internet Inspection Request from: RaChelle Meister partial inspection on 2nd flr. east units, dryer vents in wall only, bath exhaust don e 9/10/2003 10:09:31 AM
|
MEC-Aging Inspection | 8/25/2003 | 8/25/2003 | 8/25/2003 | | CANC |
Alan Hauser
|
|
|
|
MEC-Aging Inspection | 6/25/2003 | 6/25/2003 | 6/25/2003 | | NR |
Alan Hauser
|
|
|
|
Application received | | | 3/21/2003 | | |
|
|
|
|
Issue & PRINT permit | | | 3/21/2003 | | DONE |
|
|
|
|