Information based on query as of Friday, July 19, 2024.
Permit Information
Permit NumberMEC05-02814
StatusFinaled
Name TML INC
Site Address 1609 S ENTERTAINMENT
Project NameCARL'S JR
Customer Number9127
ePlanReview 
Description
HVAC for new restaurant per initial cert of value $47,269///8/31/05 BAS ///Final value is $47,882//2/7/06 LEG
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice MEC1/12/20061/12/20062/7/2006 DONE
Second Notice has not been responded to.
Second Notice MEC12/28/200512/28/20051/12/2006 DONE
First Notice has not been responded to.
First Notice12/1/200512/1/200512/28/2005 DONE
DetailsAlan Hauser
Final11/30/200512/1/200512/1/2005APASS
DetailsAlan Hauser
Scheduled by a contractor via Hello! on 11/30/2005 at 1:09:02 PM. Contact: ###-####.
Final10/28/200510/28/200510/28/2005ACANC
DetailsAlan Hauser
still need corrections completed
Final10/27/200510/27/200510/27/2005PFAIL
DetailsTroy James
all c/n items ok except for condensate traps and hinge to exhaust fan, owner to install stainless steel on wall at hood above griddle.
Final10/25/200510/26/200510/26/2005PFAIL
DetailsTroy James
Scheduled by a contractor via Hello! on 10/25/2005 at 2:48:49 PM. Contact: ###-####. c/n posted with super, temp. c of o ok
Rough-in10/25/200510/26/200510/26/2005PPASS
DetailsTroy James
Scheduled by a contractor via Hello! on 10/25/2005 at 2:48:11 PM. Contact: ###-####.
Final10/19/200510/20/200510/20/2005ACANC
DetailsTroy James
Scheduled by a contractor via Hello! on 10/19/2005 at 12:25:22 PM. Contact: ###-####. not ready
Rough-in10/19/200510/20/200510/20/2005ACANC
DetailsTroy James
Scheduled by a contractor via Hello! on 10/19/2005 at 12:24:48 PM. Contact: ###-####. not ready
Rough-in10/14/200510/17/200510/17/2005AFAIL
DetailsTroy James
Scheduled by a contractor via Hello! on 10/14/2005 at 3:32:21 PM. Contact: ###-####. grease duct to be revised so that grease will flow back to hood
Rough-in10/12/200510/13/200510/13/2005AFAIL
DetailsTroy James
Scheduled by a contractor via Hello! on 10/12/2005 at 12:40:55 PM. Contact: ###-####. grease exhaust fans termination and b-vent at roof does not meet code
Conference9/29/20059/30/20059/30/2005AFAIL
DetailsTroy James
Scheduled by a contractor via Hello! on 9/29/2005 at 9:23:01 AM. Contact: ###-####. called superintendent and told him to install hatch channel with 5/8" sheetrock with stainless steel and then the hood, protection required 18" each way from hood. Need to blanket top of hood to provide the clearance needed from trusses
Rough-in9/16/20059/19/20059/19/2005APART
DetailsLee Rice
Scheduled by a contractor via Hello! on 9/16/2005 at 12:37:33 PM. Contact: ###-####. duct work and exhausts in bath and entry ceiling area.
Application received  8/31/2005  
Issue permit  8/31/2005 DONE