Final | 1/23/2014 | 1/23/2014 | 1/23/2014 | P | PASS |
Eric Strole
|
|
|
garage code 3201 balance report is in drawer next to range Phone #: ###-#### >> Inspection requested via web by Gary Reeves
|
Final | 1/22/2014 | 1/23/2014 | 1/23/2014 | A | NR |
Eric Strole
|
|
|
Garage code is 3201 , Balance report is in kitchen drawer next to range. Phone #: ###-#### >> Inspection requested via web by Gary Reeves-need to complete air balance report
|
Final | 1/21/2014 | 1/22/2014 | 1/22/2014 | P | FAIL |
Jim Johnson
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves need air balance report on site for final correction notice on site contractor to recall when ready
|
Pressure Test | 11/29/2013 | 11/29/2013 | 11/29/2013 | P | PASS |
Troy James
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves 20# test
|
Rough-in | 11/29/2013 | 11/29/2013 | 11/29/2013 | P | PASS |
Troy James
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves contractor installed GCH95 with 90,000 btu with 5 ton blower. This is ok.
|
Pressure Test | 11/27/2013 | 11/29/2013 | 11/29/2013 | A | CANC |
Troy James
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|
Rough-in | 11/27/2013 | 11/29/2013 | 11/29/2013 | A | CANC |
Troy James
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|
Pressure Test | 11/27/2013 | 11/27/2013 | 11/29/2013 | P | CANC |
Eric Strole
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves
|
Rough-in | 11/27/2013 | 11/27/2013 | 11/29/2013 | P | CANC |
Eric Strole
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves
|
Pressure Test | 11/27/2013 | 11/27/2013 | 11/27/2013 | A | FAIL |
Eric Strole
|
|
|
20 lb gas test fail. (gauge will not zero out)
|
Rough-in | 11/27/2013 | 11/27/2013 | 11/27/2013 | A | FAIL |
Eric Strole
|
|
|
Still need heat sheild on b-vent in garage overhead. Test on pvc flue fail. Need to resubmit manual-j.
|
Pressure Test | 11/26/2013 | 11/26/2013 | 11/26/2013 | P | CANC |
Eric Strole
|
|
|
all corrections have been made, tried calling Troy, dixie and Bill about Manual J , unable to get ahold of them. Out door unit is a 4ton heat pump and will be listed as primary source of heat not the furnace. amana equipment because of cfm output requires us to put a 5 ton furnace so we get enough air across coil to keep unit from freezing up during cooling. Phone #: ###-#### >> Inspection requested via web by Gary Reeves
|
Rough-in | 11/26/2013 | 11/26/2013 | 11/26/2013 | P | CANC |
Eric Strole
|
|
|
all corrections have been made, tried calling Troy, dixie and Bill about Manual J , unable to get ahold of them. Out door unit is a 4ton heat pump and will be listed as primary source of heat not the furnace. amana equipment because of cfm output requires us to put a 5 ton furnace so we get enough air across coil to keep unit from freezing up during cooling. Phone #: ###-#### >> Inspection requested via web by Gary Reeves
|
Rough-in | 11/25/2013 | 11/25/2013 | 11/25/2013 | P | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves // need heat shield on Bvent garage overhead, need psi test on pvc flu, need to insulate tin in garage overhead, equipment no per manual J need to resubmit.
|
Pressure Test | 11/25/2013 | 11/25/2013 | 11/25/2013 | P | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves // 20# pressure test fail, guage did not 0 out
|
Pressure Test | 11/21/2013 | 11/22/2013 | 11/22/2013 | P | CANC |
Bill VanDegrift
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|
Rough-in | 11/21/2013 | 11/22/2013 | 11/22/2013 | P | CANC |
Bill VanDegrift
|
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|
Issue PAID IN FULL permit | | | 11/20/2013 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/20/2013 | | DONE |
|
|
|
This permit was created on the web by Gary Reeves
|