Final | 5/2/2014 | 5/5/2014 | 5/5/2014 | A | PASS |
Chad Schwendiman
|
|
|
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN
|
Final | 5/1/2014 | 5/1/2014 | 5/1/2014 | P | FAIL |
Chad Schwendiman
|
|
|
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN - Need make up air for the range hood, Gas shut off valve for furnace needs to be accessable, Need 6" clearance to combustables from single wall flue pipe on water heater, Need to run secondary condensate on the coil.
|
Rough-in | 1/17/2014 | 1/21/2014 | 1/21/2014 | A | PASS |
Dixie Fellows
|
|
|
399 CFM Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN..r/i ok flue test ok
|
Rough-in | 1/15/2014 | 1/17/2014 | 1/17/2014 | A | FAIL |
Eric Strole
|
|
|
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN-Test on flue fail. Missing supply in lower level bath. Need to insulate tin in crawl. What is the cfm on kitchen exhaust? Do we need make-up air? No furnace installed at this time.
|
Pressure Test | 1/15/2014 | 1/17/2014 | 1/17/2014 | A | PASS |
Eric Strole
|
|
|
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN-20 lb gas test pass
|
Issue PAID IN FULL permit | | | 1/15/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/15/2014 | | DONE |
|
|
|
This permit was created on the web by GREGORY ANDERSEN
|