Final | 8/22/2014 | 8/22/2014 | 8/22/2014 | P | PASS |
Chad Schwendiman
|
|
|
Code to get in is 2057. Please call when inspection has been completed. Thanks Joe Phone #: ###-#### >> Inspection requested via web by Jose Rodriguez
|
Pressure Test | 8/20/2014 | 8/20/2014 | 8/20/2014 | P | PASS |
Eric Strole
|
|
|
Code to get in 2057 Please call when inspection has been complete. Thanks Joe Phone #: ###-#### Inspection requested via web by Jose Rodriguez-20 lb gas test pass.
|
Pressure Test | 8/17/2014 | 8/18/2014 | 8/18/2014 | A | FAIL |
Chad Schwendiman
|
|
|
Code to get in 2057 Please call when you have completed the test Thanks Joe Phone #: ###-#### >> Inspection requested via web by Jose Rodriguez - NEED 1" CLEARANCE TO COMBUSTABLES FROM B-VENT ON FURNACE. PVC CONDENSATE DRAIN IS TOUCHING THE B-VENT AND HAS MELTED AROUND IT. NEED TO CHANGE CONDENSATE DRAIN TO NON COMBUSTABLE MATERIAL IN THIS LOCATION.
|
Issue PAID IN FULL permit | | | 8/17/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/17/2014 | | DONE |
|
|
|
This permit was created on the web by Jose Rodriguez
|