Final | 1/29/2015 | 1/30/2015 | 1/30/2015 | A | PASS |
Dixie Fellows
|
|
|
First thing in morning // Oleg Phone #: ###-####
|
Final | 1/29/2015 | 1/29/2015 | 1/29/2015 | P | FAIL |
Dixie Fellows
|
|
|
Oleg Phone #: ###-####..outside air still not connected to the kitchen hood
|
Final | 1/28/2015 | 1/28/2015 | 1/28/2015 | P | FAIL |
Dixie Fellows
|
|
|
Oleg Phone #: ###-####..the breaker to the hood doesn't work..unable to check to see if outside air is working
|
Final | 1/26/2015 | 1/26/2015 | 1/26/2015 | P | FAIL |
Dixie Fellows
|
|
|
for the fire place // Oleg Phone #: ###-####..NEED UPPER COMB AIR AT OUTSIDE EQUIPMENT..MAKE-UP AIR FOR KITCHEN EXHAUST NOT WORKING
|
Rough-in | 10/7/2014 | 10/7/2014 | 10/7/2014 | P | PASS |
Dixie Fellows
|
|
|
Oleg-please call 1 hr prior Phone #: ###-####..r/i ok..kit exhaust is still 6"
|
Rough-in | 10/1/2014 | 10/2/2014 | 10/2/2014 | A | FAIL |
Dixie Fellows
|
|
|
Please call ahead for access 1hr - Oleg Phone #: ###-####..f/p flue needs to have rise per the manuf..need cfm for kitchen exhaust
|
Rough-in | 10/1/2014 | 10/1/2014 | 10/1/2014 | P | FAIL |
Dixie Fellows
|
|
|
Oleg Phone #: ###-####..flue test failed upstairs..need to meet to discuss f/p's
|
Rough-in | 9/29/2014 | 9/30/2014 | 9/30/2014 | A | FAIL |
Chad Schwendiman
|
|
|
oleg Phone #: ###-#### - NEED 8" FRESH AIR DUCT TO RETURN AIR PLENUM, MISSING RETURN TRANSFER IN MASTER BEDROOM, NEED TO COMPLETE LINESET GOING THROUGH MASTER BATH, 5LB FLUE PRESSURE FAIL ON BOTH FURNACES, NO RANGE VENT INSTALLED, NEED 1" CLEARANCE TO B-VENT FOR FIREPLACE IN 2ND. FLOOR CHASE.
|
Issue PAID IN FULL permit | | | 9/17/2014 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 9/17/2014 | | DONE |
|
|
|
This permit was created on the web by Oleg Chervak
|