Permit Information
Permit NumberMEC16-04915
StatusFinaled
Name CAPITAL CITY HEATING & COOLING
Site Address 1421 E JEFFERSON ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Converting from wall furnace to forced air system
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/10/20174/10/20174/10/2017PPASS
DetailsBrian Scoles
Inspection requested via web by Floyd Floyd Peek
Final4/6/20174/7/20174/7/2017PFAIL
DetailsBrian Scoles
Please call Max to meet at job, ###-####, Thanks Inspection requested via web by Floyd Floyd Peek- a/C does not match manual J- flue exhaust needs to be 3' from forced air inlet-- Went over on jobsite with Max
Rough-in11/21/201611/21/201611/21/2016PPASS
DetailsBrian Scoles
Call max ###-#### to meet on the job Inspection requested via web by Floyd Floyd Peek- equipment not set- rough in pass
Pressure Test11/21/201611/21/201611/21/2016PPASS
DetailsBrian Scoles
Call max ###-#### to meet on the job Inspection requested via web by Floyd Floyd Peek- 20lb gas pass- 5lb flue pass
Conference11/21/201611/21/201611/21/2016PCANC
DetailsChad Schwendiman
Call max ###-#### to meet on the job >> Inspection requested via web by Floyd Floyd Peek Inspection cancelled from web by: Floyd Floyd Peek
Rough-in11/16/201611/16/201611/16/2016AFAIL
DetailsBrian Scoles
Call Max for door code or to meet you on the job. ###-#### Inspection requested via web by Floyd Floyd Peek
1- need approved manual J insite
2- b vent needs 1" clearance to combustibles floor and up wall
3- gas presure test below 20 lbs
4- need combustion air
5- register in kitchen along stairwell wall missing
6-need another supply register in family room basement
7- need 6" outside air to R/A plenum
8-bedroom #1 needs supply completed
9- dryer vent needs hangers every 4' and in wall and framing needs completed for ceiling
10- seal all duct work and mastic registers to floor
11- frame in around bedroom #1 R/A in closet needs finished
Went over all issues with Max onsite- left correction notice onsite
Pressure Test11/16/201611/16/201611/16/2016APASS
DetailsBrian Scoles
Call Max for door code or to meet you on the job. ###-#### Inspection requested via web by Floyd Floyd Peek- 5lb flue pass
Rough-in11/4/201611/4/201611/4/2016PCANC
DetailsChad Schwendiman
Call Max ###-#### for acess >> Inspection requested via web by Floyd Floyd Peek Inspection cancelled from web by: Floyd Floyd Peek
Issue PAID IN FULL permit  11/4/2016 DONE
Payment received via Govolutions
Application received  11/4/2016 DONE
This permit was created on the web by Floyd Floyd Peek