Permit Information
Permit NumberMEC16-05581
StatusFinaled
Name ADVANCED HEATING & COOLING
Site Address 2126 S OWYHEE AVE
Project Name 
Customer NumberTrivolis
ePlanReviewNo
Description
Addition: Install furnace and ac
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/22/20173/24/20173/24/2017APASS
DetailsBrian Scoles
Call Eric with any issues @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
Final3/20/20173/22/20173/22/2017APART
DetailsBrian Scoles
Call Eric with any issues @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- range hood needs installed and vented
Rough-in12/22/201612/23/201612/23/2016APASS
DetailsBrian Scoles
Call Eric with any issues @ 412.6613 and Call Chris Trivolis to be let into the house Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
Rough-in12/19/201612/20/201612/20/2016AFAIL
DetailsBrian Scoles
Call Eric with any issues @ 412.6613 and Call Chris Trivolis to be let into the house @ ###-#### Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- need approved manual j onsite- need combustion air in furnace room- need 1 inch clearance between insulation shield and b vent- correction notice on front window
Rough-in12/16/201612/19/201612/19/2016AFAIL
DetailsBrian Scoles
Call Eric with any issues @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- house is locked up- no access
Rough-in12/13/201612/14/201612/14/2016AFAIL
DetailsBrian Scoles
Call Eric with any issues @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- csst gas pipe can not be secured in stud bays- need csst approved nail plates- exhaust fans need to be installed and hooked up- need approved manual J onsite and submitted for approval- need combustion air in furnace room- need isulation shiel on b vent in attic with 1" clearance- need 1" clearance to combustibles at roof penetration- registers in floor need mastic- flex duct in crawl needs supported better and off ground- left correction notice on front window
Pressure Test12/13/201612/14/201612/14/2016APASS
DetailsBrian Scoles
Call Eric with any issues @ 412.6613 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- 20lb gas pass
Issue PAID IN FULL permit  12/13/2016 DONE
Payment received via Govolutions
Application received  12/13/2016 DONE
This permit was created on the web by Dawn Kalsbeek