Permit Information
Permit NumberMEC17-01976
StatusFinaled
Name AIR CARE LLC
Site Address 1825 W BEACON ST
Project Name 
Customer NumberMF-1094
ePlanReviewNo
Description
New: HVAC // Adding 1 gas pressure test 11-22-17 TCH
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final5/29/20185/30/20185/30/2018APASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
Final5/24/20185/29/20185/29/2018AFAIL
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - return transfer in front office is undersized, still need p-trap on RTU condensate
Final5/22/20185/23/20185/23/2018APART
DetailsChad Schwendiman
Whole Bldg please Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Temporary occupancy okay. Missing return/transfer ducts and grills in office area, missing condensate p-trap on rtu
Final5/21/20185/22/20185/22/2018AFAIL
DetailsChad Schwendiman
Whole building Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Missing fire damper in trash room, missing duct access doors for fire/smoke dampers in 4th floor mech room, need screws every 6" on retaining angles on dampers in 4th floor mechanical room, missing return and return transfers in office area, need to secure fans and hoods to curbs on roof, need completed generator commisioning report.
Conference5/10/20185/10/20185/10/2018ADONE
DetailsChad Schwendiman
Phone ###-#### - Discussed relocating an exhauast penetration
Final4/27/20184/27/20184/27/2018PFAIL
DetailsBen Livingston
Rooftop final please Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
condensates on 1st 2nd 3rd floor okay,
all line sets need to be supported and connected to support
Final4/17/20184/18/20184/18/2018APART
DetailsChad Schwendiman
Final inspection for 1st 2nd and 3rd floors please Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - final okay on units 300, 302, 303, 304, 305, 306, 202, 203, 204, 205, 206, 103, 104, 105, 106, 126.

Condensates not complete in units 301, 200, 201, 100, 101, 102
Conference4/13/20184/13/20184/13/2018PPASS
DetailsChad Schwendiman
Cover inspection for garage please Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover garage ceiling
Final4/3/20184/3/20184/3/2018PPART
DetailsChad Schwendiman
3rd ; 4th floors 2nd phase please Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - finals okay on units 112, 124, 320, 322, 323, 324, 325, 326, 328, 330, 332, 401, 402, 403, 405, 406, 420, 423, 425, 432
Final4/2/20184/2/20184/2/2018PPART
DetailsChad Schwendiman
partial final for phase two, floors 1,2,3 & 4 // Justin Phone #: ###-#### - final okay on units 120, 122, 123, 125, 128, 130, 132, 220, 222 223, 224, 225, 226, 228, 230, 232
CHANGE STATUS TO (ISS)  4/2/2018 DONE
Per Chad to reopen, didn't mean to final out.
Final3/28/20183/28/20183/28/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover hard lids in lobby area
Final3/23/20183/26/20183/26/2018APART
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover ceilings in fitness room and club house. Final okay on units 107, 108, 109, 110, 111, 114, 116, 118
Final3/21/20183/21/20183/21/2018PPART
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN units 408, 308, 207, 208, 209, 210, 211, 212, 214, 216, 218
Rough-in3/17/20183/19/20183/19/2018APASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Fire/smoke damper instalation and clearances okay on fourth floor south shaft.
Final3/12/20183/12/20183/12/2018APART
DetailsChad Schwendiman
3rd and 4th floor Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - apt's 307, 310, 309, 312, 314, 311, 316, 318, 407, 409, 410, 411, 412, 414, 416, 418
Rough-in3/6/20183/6/20183/6/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to sheetrock the face of the north shaft on all floors, Okay to sheetrock the face of the south east shaft on 1st-3rd floors
Rough-in3/1/20183/1/20183/1/2018APASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover south east shaft on 1st, 2nd, and 3rd floors
Rough-in2/28/20182/28/20182/28/2018PCANC
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
Rough-in2/28/20182/28/20182/28/2018APART
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover hard lids in unit 300. Need framing around fire/smoke dampers on south east shaft
Rough-in2/23/20182/26/20182/26/2018APASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover hard lids in units 100, 101, 102, 103, 104, 105, 106
Rough-in2/22/20182/22/20182/22/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - duct seal okay on exhaust shaft in north corridoor
Rough-in2/21/20182/21/20182/21/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover hard lids in units 200, 201, 202, 203, 204, 205, 206
Rough-in2/14/20182/15/20182/15/2018APASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - unit 301 okay to cover hard lids
Rough-in2/14/20182/14/20182/14/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - 302, 303, 304, 305, 306 okay to cover hard lids.
Rough-in2/13/20182/13/20182/13/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover hard lids in units 401, 402, 403, 404, 405, 406
Rough-in2/7/20182/7/20182/7/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover hard lids in units 425, 432, and 2nd floor janitors room
Rough-in2/6/20182/6/20182/6/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover hard lids in units 420, 423, and the 4th floor janitors room
Rough-in2/5/20182/5/20182/5/2018APASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover walls and TGI's in unit 300
Rough-in2/1/20182/1/20182/1/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN okay to cover hard lids in units 320, 325, 330, 332
Rough-in1/30/20181/31/20181/31/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover hard lids in units 132, 232, 322, 323, 324, 326, 328
Rough-in1/26/20181/26/20181/26/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover hard lids in units 216, 218, 220, 222, 223, 224, 226, 228, 225, 230
Rough-in1/24/20181/24/20181/24/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover hard lid in unit 125
Rough-in1/23/20181/23/20181/23/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - hard lids okay to cover in 122, 123, 124, 126, 128
Rough-in1/18/20181/18/20181/18/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover hard lids in units 116, 118, 120
Rough-in1/16/20181/16/20181/16/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover walls and TGI's in units 402, 403, 404, 405, 406
Rough-in1/11/20181/11/20181/11/2018PPASS
DetailsChad Schwendiman
3rd floor ; 401 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover walls and TGI's in units 302, 303, 304, 305, 306, 401
Rough-in1/9/20181/9/20181/9/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover hard lids in units 407, 408, 409, 410, 411, 412, 414, 416, 418
Rough-in1/5/20181/5/20181/5/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover walls and tgi's in units 200-206m and 301
Rough-in1/3/20181/3/20181/3/2018PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN 0kay to cover walls and bottom of TGI's in units 100, 101, 102, 103, 104, 105, 106
Rough-in12/27/201712/27/201712/27/2017PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover hard lids 307,308,309, 310, 311, 312, 314, 316, 318
Rough-in12/11/201712/12/201712/12/2017APASS
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
prerock 325,330,332,420,423,425
Rough-in12/8/201712/8/201712/8/2017PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover walls and TGI's in units 322, 326, 328
Rough-in12/7/201712/7/201712/7/2017PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN okay to cover walls and TGI's in units 320, 323, 324
Rough-in12/4/201712/5/201712/5/2017PCANC
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
Rough-in12/4/201712/5/201712/5/2017APASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN okay to cover walls and tgi's in units 123, 124, 125, 126, 128, 130, 132, 223, 224, 225, 226, 228, 230, 232
Rough-in12/1/201712/1/201712/1/2017PPASS
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
207-214 okay
Pressure Test11/27/201711/27/201711/27/2017PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - 60lb gas
Rough-in11/27/201711/27/201711/27/2017PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover bottomg of TGI's and walls in units 120, 122, 220, 222
Rough-in11/22/201711/24/201711/23/2017PCANC
DetailsChad Schwendiman
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN Inspection cancelled from web by: GREGORY ANDERSEN
Pressure Test11/22/201711/24/201711/23/2017PCANC
DetailsChad Schwendiman
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN Inspection cancelled from web by: GREGORY ANDERSEN
Pressure Test11/22/201711/27/201711/22/2017ACANC
DetailsChad Schwendiman
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN Inspection cancelled from web by: GREGORY ANDERSEN
Rough-in11/22/201711/22/201711/22/2017PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Framing around fire/smoke on 1st floor okay
Rough-in11/20/201711/21/201711/21/2017PFAIL
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Need to frame around fire/smoke damper per manufactures instructions
Rough-in11/15/201711/15/201711/15/2017PPASS
DetailsBen Livingston
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
107 - 112 okay
Rough-in11/6/201711/6/201711/6/2017PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover bottom of tgi's and walls in units 116, 118, 216, 218, 316, 318, 416, 418.
Conference10/30/201710/30/201710/30/2017ADONE
DetailsChad Schwendiman
Phone ###-#### - Spoke with Rob about Dryer duct terminations
Rough-in10/25/201710/25/201710/25/2017PPASS
DetailsChad Schwendiman
4th floor rough-in please Phone #: ###-#### Inspection requested via web by GREGORY - okay to cover bottom of TGI's in units 407, 408, 409, 410, 411, 412, 414
Rough-in10/9/201710/9/201710/9/2017PPASS
DetailsBen Livingston
3rd floor Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
prerock rooms 307,-314
Rough-in10/2/201710/3/201710/3/2017PPASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - okay to cover bottom of TGI's in units 207-212, & 214
Rough-in9/27/20179/28/20179/28/2017APASS
DetailsChad Schwendiman
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN - Okay to cover the bottom of the TGI's in units 111, 112, 114, 109, 110, 107, 108.
Conference8/2/20178/4/20178/4/2017ADONE
DetailsChad Schwendiman
Rob Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
Issue PAID IN FULL permit  5/24/2017 DONE
Payment received via Govolutions
Application received  5/24/2017 DONE
This permit was created on the web by GREGORY ANDERSEN
First Notice5/30/20185/30/2018   
DetailsChad Schwendiman