Final | 11/7/2017 | 11/8/2017 | 11/8/2017 | A | PASS |
Brian Scoles
|
|
|
key is back left of garage under rock thank you Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
Final | 11/6/2017 | 11/6/2017 | 11/6/2017 | P | FAIL |
Brian Scoles
|
|
|
left corner of garage has a key under a rock Inspection requested via web by Aaron Alandt- need to insulate 3 sides and top of filter box excluding access door- single wall pipe needs 6" clearance to pvc piping in furnace closet- left correction notice on furnace
|
Rough-in | 7/26/2017 | 7/27/2017 | 7/27/2017 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Ben Welgan
|
Pressure Test | 7/26/2017 | 7/27/2017 | 7/27/2017 | A | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Ben Welgan- 20lb gas pass- 5lb flue pass
|
Rough-in | 7/25/2017 | 7/26/2017 | 7/26/2017 | A | FAIL |
Brian Scoles
|
|
|
EARLY AM INSPECTION IF POSSIBLE PLEASE THANK YOU Phone #: ###-#### Inspection requested via web by Ben Welgan- insulation shield 2nd floor needs 1" clearance to b vent and secured and all pipe enclosed- b vent 2nd floor needs 1" clearance to combustibles at floor level- left correction notice front window
|
Pressure Test | 7/25/2017 | 7/26/2017 | 7/26/2017 | A | PART |
Brian Scoles
|
|
|
EARLY AM INSPECTION IF POSSIBLE PLEASE THANK YOU Phone #: ###-#### Inspection requested via web by Ben Welgan- 20lb gas pass- 5lb flue fail guage at 2 psi-
|
Issue PAID IN FULL permit | | | 6/30/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/30/2017 | | DONE |
|
|
|
This permit was created on the web by Ben Welgan
|