Permit Information
Permit NumberMEC17-03204
StatusFinaled
Name THE TRADE SOURCE
Site Address 2770 W NEFF ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Furnace, AC, Dryer Vent, Multiple Baths, Dual Zone, Auto Fresh Air, and Transfers
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/5/201710/5/201710/5/2017APASS
DetailsBen Livingston
Please text me 1hr. before the estimated inspection time. 208.412.6713 Thank you!! Phone #: ###-#### Inspection requested via web by Richard Cusimano
Final9/25/20179/25/20179/25/2017AFAIL
DetailsBen Livingston
Garage code 2770. Phone #: ###-#### Inspection requested via web by Richard Cusimano
fresh air needs to be ins. in mechanical closet, couldnt find blast test or balance report
(F) Reprint permit  7/25/2017 DONE
Rough-in7/24/20177/24/20177/24/2017PPASS
DetailsBrian Scoles
robert 208 412 6713- furnace and ac not set yet- contractor working with builder in furnace/linen closet upstairs will be complete by final-
Pressure Test7/24/20177/24/20177/24/2017PPASS
DetailsBrian Scoles
2olb gas pass- 5lb flue pass
Rough-in7/21/20177/24/20177/24/2017AFAIL
DetailsBrian Scoles
Richard Phone #: ###-####- gas at zero needs 30lb guage not 15lb- csst cant penetrate appiance fireplace with protective sleeve- need to pressure test flue 2nd floor- need approved nail plate in laundry room for csst gas piping- dryer vent is oval at top plate need to maintain 4" round- exhaust duct in laundry room needs supported- master bedroom need RA or transfer grill installed not shown on manual J- supply main 2nd floor needs finished to furnace room-lineset needs strapped up in attic- bedroom 2nd floor west side needs supply register leveled and supported better at ceiling- supply joints needs sealed 2nd floor on elbows- left correction notice in garage on supply line
Pressure Test7/21/20177/24/20177/24/2017AFAIL
DetailsBrian Scoles
Richard Phone #: ###-####- gas guage a 0 and needs to be 30lb guage not 15 lb- flue needs tested 2nd floor
Issue PAID IN FULL permit  7/21/2017 DONE
Application received  7/20/2017 DONE