Final | 7/9/2018 | 7/10/2018 | 7/10/2018 | A | PASS |
Jack Reynolds
|
|
|
Inspection requested via web by jeff jedlick- drip leg in gas line upstairs ok- both furnace ac coil co ok
|
Final | 6/28/2018 | 6/29/2018 | 6/29/2018 | P | FAIL |
Jack Reynolds
|
|
|
Call homeowner sid at 208 841 5808 for access Inspection requested via web by jeff jedlick- furnace upstairs needs a drip leg installed in gas line after shut off valve
|
Final | 5/3/2018 | 5/4/2018 | 5/4/2018 | P | CANC |
Jack Reynolds
|
|
|
>> Inspection requested via web by jeff jedlick Inspection cancelled from web by: jeff jedlick
|
Mec-Aging Inspection | 5/3/2018 | 5/3/2018 | 5/3/2018 | | CANC |
Chad Schwendiman
|
|
|
WIP
|
Rough-in | 9/7/2017 | 9/8/2017 | 9/8/2017 | P | PASS |
Brian Scoles
|
|
|
Inspection requested via web by jeff jedlick
|
Rough-in | 9/6/2017 | 9/7/2017 | 9/7/2017 | P | FAIL |
Brian Scoles
|
|
|
Roy will be on the job all day, his number is ###-#### Phone #: ###-#### Inspection requested via web by jeff jedlick- need to hook up ex fan 2nd floor laundry room- need combustion air minimum of 100 sq inches high and low in basement- need to install 1 supply boot in basement- duct work exposed in basement- no equipment set
|
Pressure Test | 9/7/2017 | 9/7/2017 | 9/7/2017 | P | PASS |
Brian Scoles
|
|
|
20lb gas pass- 5lb flue x2 in basement pass- 5lb flue 2nd floor pass- no equipment set
|
Issue PAID IN FULL permit | | | 8/24/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/24/2017 | | DONE |
|
|
|
This permit was created on the web by jeff jedlick
|