Final | 12/27/2017 | 12/28/2017 | 12/28/2017 | A | PASS |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
Final | 12/21/2017 | 12/26/2017 | 12/26/2017 | P | FAIL |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt condensate from pump tubing needs to be connected to drain line
|
Final | 12/21/2017 | 12/21/2017 | 12/21/2017 | P | FAIL |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt - Duct for range hood needs to be Galvinized, stainless steel or copper with a smoth interior finish. Need to complete condensate drains on coil, need UV protection on linesets.
|
Rough-in | 10/30/2017 | 10/30/2017 | 10/30/2017 | P | PASS |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
Pressure Test | 10/27/2017 | 10/27/2017 | 10/27/2017 | P | PASS |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt - 20lb gas
|
Rough-in | 10/27/2017 | 10/27/2017 | 10/27/2017 | P | FAIL |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt - Need insulation shield on B-vent, missing exhaust fan in basement bathroom, Dryer vent?
|
Issue PAID IN FULL permit | | | 10/27/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/27/2017 | | DONE |
|
|
|
This permit was created on the web by Joseph Profitt
|