Final | 2/22/2018 | 2/23/2018 | 2/23/2018 | A | PASS |
Ben Livingston
|
|
|
Phone #: ###-#### Inspection requested via web by Heath Taylor
|
Final | 2/22/2018 | 2/22/2018 | 2/22/2018 | P | FAIL |
Ben Livingston
|
|
|
The final inspection is ready. Please let me know if there''s any issues? thank you so much, Heath Taylor T ; T Heating and Cooling Phone #: ###-#### Inspection requested via web by Heath Taylor condencer needs to be minimume of 3' away from gas meter, vent on furnace is back graded in mechanical room
|
Rough-in | 12/11/2017 | 12/11/2017 | 12/11/2017 | P | PASS |
Ben Livingston
|
|
|
Heath Phone #: ###-#### 5lb flue rough in
|
Rough-in | 12/8/2017 | 12/8/2017 | 12/8/2017 | P | NR |
Ben Livingston
|
|
|
Heath Phone #: ###-####
|
Rough-in | 12/7/2017 | 12/7/2017 | 12/7/2017 | P | FAIL |
Ben Livingston
|
|
|
Heath Phone #: ###-#### need flue pressure test on furnace flue, natural draft water heater flue to much horizontal piping, clearance to combustables also
|
Issue PAID IN FULL permit | | | 12/7/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/7/2017 | | DONE |
|
|
|
This permit was created on the web by Heath Taylor
|