Final | 6/13/2018 | 6/14/2018 | 6/14/2018 | A | PASS |
Jack Reynolds
|
|
|
Blast Witness at 9AM Logan will be there to let you in the home:) thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- Man J ok- line set seal ok- duct blast ok
|
Final | 5/31/2018 | 6/1/2018 | 6/1/2018 | P | FAIL |
Jack Reynolds
|
|
|
AC: 1406 Phone #: ###-#### Inspection requested via web by Gary Reeves- condensate drain for upstairs unit is missing- need a duct blast report on upstairs unit- need updated Man J for upstairs unit- lineset penetration on west side needs sealed
|
Final | 4/20/2018 | 4/23/2018 | 4/23/2018 | P | FAIL |
Chad Schwendiman
|
|
|
AC:7354 Phone #: ###-#### Inspection requested via web by Gary Reeves - No air balance reports on site, need duct blast on upstairs furnace, Need to complete combustion air piping for down stairs furnace, need combustion air for upstairs furnace and water heater
|
Rough-in | 1/25/2018 | 1/25/2018 | 1/25/2018 | P | PASS |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves
|
Rough-in | 1/24/2018 | 1/24/2018 | 1/24/2018 | P | FAIL |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - Supply run outs in master bath and wic don't match the manual J. Need to remove spray foam from around fireplace vent.
|
Pressure Test | 1/16/2018 | 1/17/2018 | 1/17/2018 | P | PASS |
Troy James
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves
|
Rough-in | 1/16/2018 | 1/17/2018 | 1/17/2018 | P | FAIL |
Troy James
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves Need to provide manual j report that matches what and how it was installed on site
|
Pressure Test | 1/15/2018 | 1/16/2018 | 1/16/2018 | A | PART |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - 20lb gas pass, 5lb flue pass for upstairs units, Need to pressure test water heater flue. basement furnace flue pressure test fail.
|
Rough-in | 1/15/2018 | 1/16/2018 | 1/16/2018 | A | FAIL |
Chad Schwendiman
|
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - Need approved Manaul J onsite. Need to pressure test water heater flue. basement furnace flue pressure test fail.
|
Issue PAID IN FULL permit | | | 12/8/2017 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/8/2017 | | DONE |
|
|
|
This permit was created on the web by Gary Reeves
|
Telephone call | | | 12/8/2017 | | DONE |
|
|
|
Sent an email to legendheatingandair@gmail.com, mail box was full, stating that this permit needs to be pulled by fixtures not sqft
|